Degradation Kinetics, In Vitro Dissolution Studies, and Quantification of Praziquantel, Anchored in Emission

Panikumar D Anumolu1, Sunitha Gurrala1, Ceema Mathew1

  • 1Osmania University, Gokaraju Rangaraju College of Pharmacy, Department of Pharmaceutical Analysis, Hyderabad, India.

Abstract

Related Concept Videos

In Vitro Drug Dissolution: Alternative Methods01:17

In Vitro Drug Dissolution: Alternative Methods

Alternative drug dissolution methods include the rotating bottle, intrinsic dissolution test, peristalsis, and the Franz diffusion cell method. The rotating bottle method involves meticulously rotating tightly capped controlled-release beads in a temperature-controlled bath. Periodic decanting of samples allows for residue assay, followed by refilling with fresh medium and testing at various pH levels to emulate the gastrointestinal tract conditions.In contrast, the intrinsic dissolution test...
140
Drug Dissolution: Requirements and Profile Comparison01:14

Drug Dissolution: Requirements and Profile Comparison

The acceptance criteria for dissolution profile data are anchored in Q values, representing the percentage of drug dissolved within a specified period. This assessment unfolds in three stages:First Stage: The test passes if all six drug dosage units are equal to or greater than Q plus 5%; otherwise, the sample proceeds to the second stage.Second Stage: The average of twelve units must be equal to or greater than Q, with no unit falling below Q - 15% to pass; if not, it progresses to the final...
172
In Vitro Drug Dissolution: Compendial Testing Models II01:09

In Vitro Drug Dissolution: Compendial Testing Models II

Various dissolution methods are utilized to assess a drug’s dissolution rate, including the flow-through cell, paddle-over-disk, cylinder, and reciprocating disk methods.The flow-through cell apparatus (USP (United States Pharmacopeia) method 4) comprises a reservoir for the dissolution medium and a pump that propels the medium through the cell containing the test sample. This method is crucial for assessing modified-release dosage forms with minimally soluble active ingredients,...
151
Fluorescence and Phosphorescence: Instrumentation01:25

Fluorescence and Phosphorescence: Instrumentation

Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.