Objectives:
The electro-oxidation behavior of the non-steroidal anti-inflammatory drug tenoxicam (TX) was studied on multiwalled carbon nanotube (MWCNT)-modified glassy carbon electrode (GCE) by cyclic voltammetry, differential pulse voltammetry (DPV), and square wave voltammetry (SWV).
Materials And Methods:
The GCE was modified with MWCNT for sensitive determination of TX by voltammetric methods.
Results:
The current peaks for TX occurred at around 0.520 V for DPV and 0.570 V for SWV when the potential was scanned in the positive direction. The oxidation process of TX showed irreversible and diffusion-controlled behavior. The linear responses were obtained in the range from 2×10-7 to 1×10-5 M with the limit of detection (LOD) 1.43×10-9 for DPV and from 8×10-9 to 8×10-6 with the LOD 9.97×10-10 for SWV in 1 M acetate buffer solution at pH 5.5.
Conclusion:
Fully validated DPV and SWV were successfully applied for the determination of TX from pharmaceutical dosage form and yielded satisfying results.
More Related Videos
08:38Quantification of the Immunosuppressant Tacrolimus on Dried Blood Spots Using LC-MS/MS
Published on: November 8, 2015
09:24Application and Methodology of the Non-destructive 19F Time-domain NMR Technique to Measure the Content in Fluorine-containing Drug Products
Published on: August 22, 2017
Related Concept Videos
Therapeutic Drug Monitoring: Drug Analysis Methods
Drug Concentrations: Measurements
Plasma...
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Noncompartmental Analysis: Mean Transit, Absorption and Dissolution Time
One of the key parameters is the mean transit time (MTT), which refers to the total duration required for drug molecules to transit through the body. MTT is determined by calculating the ratio of the area under the moment curve to the area...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Drug Dissolution: Requirements and Profile Comparison