Development of Screen-Printed Electrode Biosensor for Rapid Determination of Triglyceride Content in Coconut Milk
D Manoj1, Ishita Auddy1, Shubham Nimbkar1
1Indian Institute of Food Processing Technology, Thanjavur, 613005 Tamil, India.
Abstract:
The screen-printed electrode biosensor was developed for triglyceride determination in coconut milk. The biosensor was developed by adding lipase, glycerol-3-phosphate (GPO), and glycerol kinase (GK), which is immobilized to a gelatin solution. The concentration of triglyceride is found to be linear to the current produced. The developed screen-printed electrode biosensor showed the optimum response for pH 7.0, 45 mg amount of gelatin, 2.5% glutaraldehyde concentration solution. The developed biosensor was able to find triolein concentrations 0.1 to 1.5 mM. The correlation obtained between these two methods was 93% which was found to be good.