Fabrication and Testing of Photonic Thermometers
Published on: October 24, 2018
Open source, low-cost device for thermometric titration with non-contact temperature measurement
Keiti O Alessio1, Bruna Tischer2, Mônica Voss3
1Departamento de Tecnologia e Ciência Dos Alimentos, Universidade Federal de Santa Maria, 97105-900, Santa Maria, RS, Brazil; Departamento de Química, Universidade Federal de Santa Maria, 97105-900, Santa Maria, RS, Brazil.
Abstract:
This work proposes a simple device for thermometric titration using a contactless sensor. A low-cost infrared sensor (around $5) was adapted in a disposable, polystyrene vessel for monitoring the temperature to determine the endpoint of neutralization, redox, and complexation titrations, using a homemade syringe pump to titration control. Open-source software was developed to control the device using the Raspberry Pi platform and to perform automatic endpoint determination. The influence of sample volume, the flow rate of titrant, and sensor distance from the solution were evaluated to lower the variation among measurements. The parameters chosen in this regard were 10 mL of sample, 0.8 mL min-1 of titrant solution flow rate, and 3 cm of distance from the sensor to the solution. Results for the determination of the acidity of sauces and the ascorbic acid and calcium content of pharmaceutical products were compared with those from official compendia. The performance of the sensor also was compared with an infrared camera. The proposed method agreed with conventional ones to an extent ranging from 93% to 106%. The robust analytical performance and low cost of the system are essential features that could broaden the use of enthalpimetric analysis in several laboratories.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Thermosensation
Controlled-Current Coulometry: Coulometric Titration
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...