Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Dysrhythmias IV: Characteristics of Bradyarrhythmias01:18

Dysrhythmias IV: Characteristics of Bradyarrhythmias

376
Bradyarrhythmias are cardiac rhythm disorders characterized by a slower-than-normal heart rate, typically defined as fewer than 60 beats per minute. Some of which are discussed here:Sinus BradycardiaSinus bradycardia presents a heart rate lower than 60 beats per minute, with a regular rhythm originating from the SA node. The ECG typically shows normal P waves preceding each QRS complex, a normal PR interval (0.12 to 0.20 seconds), and a normal QRS duration (0.06 to 0.10 seconds).First-Degree AV...
376
Assessment of apical radial pulse01:25

Assessment of apical radial pulse

1.1K
Apical-Radial (A-R) Pulse Assessment
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
1.1K
Pulse rhythm01:30

Pulse rhythm

1.2K
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
1.2K
Assessment of apical pulse01:17

Assessment of apical pulse

1.8K
Assessing the Apical Pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
1.8K
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias01:25

ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias

345
Arrhythmia is a condition characterized by an irregular heart rhythm, with ECG changes that differ based on its origin and nature. The types of arrhythmias discussed below include atrial, junctional, and ventricular arrhythmias.Atrial ArrhythmiasPremature Atrial Complexes (PACs): PACs are early atrial beats caused by stress, caffeine, alcohol, electrolyte imbalances, hypoxia, hyperthyroidism, or certain medications (e.g., bronchodilators and decongestants). The ECG shows early P waves with an...
345
Mitral Regurgitation I: Introduction01:20

Mitral Regurgitation I: Introduction

274
Mitral regurgitation is characterized by the backward circulation of blood from the left ventricle to the left atrium during systole, a phase of the cardiac cycle when the heart contracts and pumps blood out of the chambers. This abnormal flow occurs primarily due to the dysfunction of the mitral valve or its supporting structures, which include the mitral leaflets, chordae tendineae, annulus, and papillary muscles.Etiology and Mechanisms:Primary Mitral Regurgitation: This type arises from...
274

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

UHF-ECG Outperforms QRS Duration and Morphology in Predicting Responders to Biventricular Cardiac Resynchronization Therapy.

JACC. Clinical electrophysiology·2026
Same author

Conduction System Disease: Fascicles to Complete Block.

JACC. Case reports·2026
Same author

Anatomical considerations for left bundle branch area pacing.

Heart rhythm·2026
Same author

Long-term performance of conduction system pacing in patients with congenital heart disease.

Heart rhythm·2026
Same author

Optimal pace timing for left bundle branch area pacing with or without an additional LV lead: results from the CSPOT study.

Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology·2026
Same author

Safety and performance of a novel ICD lead for left bundle branch area pacing: Results from the ASCEND CSP trial.

Heart rhythm·2026

Related Experiment Video

Updated: Dec 20, 2025

Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
12:45

Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing

Published on: December 11, 2017

10.8K

Left bundle branch pacing.

Shunmuga Sundaram1, Pugazhendhi Vijayaraman2

  • 1Velammal Medical college, Madurai, Tamil Nadu, India.

Herzschrittmachertherapie & Elektrophysiologie
|May 28, 2020
PubMed
Summary
This summary is machine-generated.

Left bundle branch pacing (LBBP) offers a physiological alternative to traditional right ventricular pacing, potentially improving heart function and reducing heart failure hospitalizations. This review details LBBP

Keywords:
Conduction system pacingDeep septal pacingHis bundle pacingImplantation techniquesLBBP

More Related Videos

Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
10:17

Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System

Published on: April 11, 2025

1.5K
Optocardiography and Electrophysiology Studies of Ex Vivo Langendorff-perfused Hearts
09:52

Optocardiography and Electrophysiology Studies of Ex Vivo Langendorff-perfused Hearts

Published on: November 7, 2019

13.5K

Related Experiment Videos

Last Updated: Dec 20, 2025

Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
12:45

Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing

Published on: December 11, 2017

10.8K
Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
10:17

Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System

Published on: April 11, 2025

1.5K
Optocardiography and Electrophysiology Studies of Ex Vivo Langendorff-perfused Hearts
09:52

Optocardiography and Electrophysiology Studies of Ex Vivo Langendorff-perfused Hearts

Published on: November 7, 2019

13.5K

Area of Science:

  • Cardiology
  • Electrophysiology
  • Medical Devices

Background:

  • Chronic right ventricular (RV) pacing causes dyssynchrony, increasing risks of heart failure and atrial arrhythmias.
  • His bundle pacing (HBP) is physiological but has limitations like lead stability and a steep learning curve.
  • Left bundle branch pacing (LBBP) emerges as a novel technique to overcome HBP limitations.

Purpose of the Study:

  • To review the criteria and methodology for successful left bundle branch pacing (LBBP).
  • To highlight LBBP as a potential alternative to conventional pacing methods.
  • To discuss the safety and efficacy of LBBP in cardiac conduction system disease.

Main Methods:

  • Review of literature on left bundle branch pacing (LBBP) techniques.
  • Detailed discussion of criteria for left bundle branch (LBB) capture.
  • Description of pacing hardware, including Medtronic SelectSecure®3830 lead and C315His®/C304His® sheaths.

Main Results:

  • LBBP demonstrates feasibility, safety, and efficacy, offering low pacing thresholds.
  • Left bundle potential is typically demonstrable, except in specific heart block or bundle branch block scenarios.
  • LBBP shows promise in patients with left ventricular dysfunction and conduction abnormalities.

Conclusions:

  • LBBP is a safe and effective technique for pacing the cardiac conduction system.
  • It presents a viable alternative to His bundle pacing and biventricular pacing.
  • Further randomized trials are needed to confirm long-term safety and clinical outcomes compared to traditional pacing.