Relationship Between Geometric and Aerodynamic Particle Size Distributions in the Formulation of Solution and
Hiroyuki Yoshida1, Akiko Usui2, Yasuhiro Abe2
1Division of Drugs, National Institute of Health Sciences, Tonomachi 3-25-26, Kawasaki-ku, Kawasaki-shi, Kanagawa, 210-9501, Japan. h.yoshida@nihs.go.jp.
Abstract:
The relationship between the geometric particle size distribution (GPSD) and the aerodynamic particle size distribution (APSD) of commercial solution and suspension metered-dose inhaler (MDI) formulations was assessed to clarify the use of GPSD to estimate the APSD. The size distribution of particles discharged from four suspension and four solution MDIs was measured using the Inas®100 light-scattering spectrometer and a Next Generation Impactor. The conversion factor was calculated by measuring the GPSD and APSD of MDIs. The morphology and physical properties of MDIs were studied using scanning electron microscopy (SEM) and differential scanning calorimetry (DSC). Six of the eight MDIs showed similar conversion factor profiles, irrespective of their composition and formulation types. Applying the conversion factor obtained from one of the six MDIs resulted in a particle size distribution comparable to each APSD except for some formulations. The two other solution MDIs, which contained citric acid, had much higher and variable conversion factors. SEM images and DSC scans of the solids obtained by nebulization of the solutions containing beclomethasone and/or citric acid showed the formation of a paste-like amorphous solid. These results indicated that APSD of solution and suspension MDIs that form rigid particles may be estimated by using the conversion factor and GPSD. Contrarily, the estimation is more difficult in formulations that tend to lose the particle structure during the measurement.
Related Concept Videos
Factors Affecting Dissolution: Particle Size and Effective Surface Area
Inhaled Medications
Pharmaceutical Alternatives: Polymorphic Form-Related and Particle Size-Related Therapeutic Nonequivalence
Precipitate Formation and Particle Size Control
The obtained precipitate should be either a pure substance of known composition or easily converted to one by a simple process, such as ignition or drying. In addition, the precipitate should be insoluble and easily filterable. In general, filterability...
Dose Size and Dosing Frequency: Determination Methods
Formulation and Manufacturing Process: Physical Attributes of Generic Tablets and Capsules