Related Experiment Video
Updated: Dec 20, 2025

Electromagnetic Navigation Transthoracic Nodule Localization for Minimally Invasive Thoracic Surgery
Published on: May 4, 2022
CT-guided microcoil localization for pulmonary nodules before VATS: a retrospective evaluation of risk factors for
Yanyan Xu1, Lingchuan Ma2, Hongliang Sun3
1Department of Radiology, China-Japan Friendship Hospital, No.2 Yinghua East Street, Chaoyang District, Beijing, 100029, China.
Objectives:
To summarize the experiences of CT-guided microcoil localization before video-assisted thoracoscopic surgery (VATS) and to investigate the risk factors associated with pleural marking failure.
Methods:
Totally, 249 consecutive patients with 279 pulmonary nodules who underwent CT-guided microcoil localization prior to VATS were enrolled in this study. According to intraoperative observation, all the nodules were divided into two groups. The clinical characteristics and microcoil localization procedure-related variables of the nodules were analyzed by univariate analysis and multivariate logistic regression analysis to screen the independent factors associated with procedure results.
Results:
Among the 279 nodules, 28 failed to observe the proximal end of the microcoil deployed on visceral pleura during VATS. The logistic regression revealed that needle-pleura angle (≤ 30°: OR = 39.022, p = 0.003), pleura-microcoil distance (≤ 10 mm: OR = 87.054, p < 0.001; 10~20 mm: OR = 10.088, p = 0.010), and presence of pleural indentation (OR = 21.623, p < 0.001) were independent risk factors for pleural marking failure.
Conclusions:
CT-guided microcoil localization for pulmonary nodules is a safe and effective procedure. Small needle-pleura angle (≤ 30°), pleura-microcoil distance (≤ 20 mm), and the presence of pleural indentation during the procedure are significant risk factors contributing to microcoil pleura marking failure.
Key Points:
• CT-guided microcoil localization for pulmonary nodules was a safe and effective procedure. • CT-guided microcoil localization for pulmonary nodules yielded low complication rates. • Small needle-pleura angle, short pleura-microcoil distance, and the presence of pleural indentation were contributing to pleura marking failure.
Related Concept Videos
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...

