Transbaffle/transconduit puncture using a simple CARTO-guided approach without echocardiography in patients with

Mikael Laredo1, Victor Waldmann2,3, Gilles Soulat4

  • 1Unité de Rythmologie, Institut de Cardiologie, Groupe Hospitalier Pitié-Salpêtrière, Sorbonne Université, AP-HP, Paris, France.

Insights

This study shows that computed tomography (CT) 3D reconstruction merged with electro-anatomical mapping (EAM) enables safe transbaffle/transconduit puncture for catheter ablation (CA) in complex congenital heart disease (CHD) patients.

Area of Science:

  • Cardiology
  • Medical Imaging
  • Electrophysiology

Background:

  • Catheter ablation (CA) for atrial tachyarrhythmias (ATs) in complex congenital heart disease (CHD) patients presents significant technical challenges, particularly for transbaffle or transconduit punctures.
  • Traditional methods often rely on intra-procedure echocardiographic guidance, which may not always be optimal.

Purpose of the Study:

  • To evaluate the feasibility and safety of performing transbaffle and transconduit punctures for CA in CHD patients.
  • To assess a novel technique combining computed tomography (CT) three-dimensional (3D) reconstruction with electro-anatomical mapping (EAM) for guidance, eliminating the need for per-procedure echocardiography.

Main Methods:

  • Eighteen CHD patients (12 atrial-switch, 6 Fontan surgery) undergoing CA for ATs requiring antegrade approach with intracardiac puncture were included.
  • Cardiac CT with 3D reconstruction was merged with EAM data to precisely guide the ablation catheter to the optimal puncture site.
  • Punctures were performed under fluoroscopic guidance, with balloon expansion used for transconduit punctures and in select transbaffle cases.

Main Results:

  • The combined CT 3D reconstruction and EAM technique facilitated successful transbaffle/transconduit punctures in all cases.
  • Seventeen intra-atrial reentrant tachycardias and 9 focal ATs were successfully ablated without acute complications.
  • Median time to pulmonary atrium access was 78.5 minutes, with a median total fluoroscopy time of 23 minutes.

Conclusions:

  • Transbaffle and transconduit punctures are feasible and safe in complex CHD patients using a straightforward technique.
  • The integration of CT 3D reconstruction with EAM provides effective guidance for these challenging procedures, obviating the need for intra-procedure echocardiography.
Abstract