Related Experiment Video
Updated: Dec 20, 2025

Echocardiographic Measurement of Right Ventricular Diastolic Parameters in Mouse
Published on: April 27, 2019
Feasibility in the echocardiographic estimation of parameters of the right ventricle in prone position
Luis E Santos-Martínez1,2, Gastón Mendoza-Copa1, Edgar García-Cruz1
1Departamento de Cuidados Intensivos Posquirúrgicos Cardiovasculares, Instituto Nacional de Cardiología Ignacio Chávez, Secretaría de Salubridad y Asistencia. Ciudad de México, México.
Background:
Echocardiographic cardiac parameters in the prone position are usually obtained with an esophageal probe. The feasibility of obtaining them by means of a transthoracic approach is unknown.
Objective:
Estimating the feasibility to obtain parameters of the right ventricle by transthoracic echocardiography in prone position on the subject.
Methods:
Pilot design of consecutive case series without cardiopulmonary disease. Demographic, vital signs and echocardiographic variables were defined in the ventral initial, prone and ventral final decubitus positions. The data are shown with averages and standard deviations, and frequencies and percentages according to the variable. The differences between the positions were calculated with ANOVA of repeated samples and adjustment of Bonferroni test. Intra-subject variability was obtained by the Bland-Altman procedure and its 95% confidence interval.
Results:
We studied 50 subjects, 44 (88%) males, age 30 ± 6 years and body mass index 25.65 ± 2.71 kg/m2. Tricuspid annular plane systolic excursion (TAPSE) and S'-wave were measured 100% of the time. The vital signs and echocardiographic variables according to the position had differences in: heart rate (74 ± 9 vs. 77 ± 9 vs. 75 ± 8 beats/min), partial oxygen saturation (94.40 ± 1.70 vs. 96.64 ± 1.79 vs. 95.32 ± 1.36%) and mean systemic blood pressure (65.33 ± 5.38 vs. 67.69 ± 6.31 vs. 65.29 ± 5.62 mmHg); TAPSE (19.74 ± 3.24 vs. 21.60 ± 2.97 vs. 19.44 ± 2.84 mm), mean difference (bias) 0 (2, -2.0) and S'-wave (13.52 ± 1.87 vs. 15.02 ± 2.09 vs. 13.46 ± 1.55 cm/s), mean difference (bias) -0.46 (1.21, -2.14) respectively.
Conclusions:
Obtaining right ventricle parameters by transthoracic ecocardiopraphy is feasible in the prone position.
More Related Videos
10:33Assessment of Right Ventricular Structure and Function in Mouse Model of Pulmonary Artery Constriction by Transthoracic Echocardiography
Published on: February 3, 2014
07:11Morphological and Functional Assessment of the Right Ventricle Using 3D Echocardiography
Published on: October 28, 2020
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Cardiac Catheterization II: Right Heart Catheterization