Criterion Validity, and Interunit and Between-Day Reliability of the FLEX for Measuring Barbell Velocity During
Jonathon Weakley1,2, Daniel Chalkley1, Rich Johnston1,2
1School of Behavioural and Health Sciences, Australian Campus University, Brisbane, Queensland, Australia.
Abstract:
Weakley, J, Chalkley, D, Johnston, R, García-Ramos, A, Townshend, A, Dorrell, H, Pearson, M, Morrison, M, and Cole, M. Criterion validity, and interunit and between-day reliability of the FLEX for measuring barbell velocity during commonly used resistance training exercises. J Strength Cond Res 34(6): 1519-1524, 2020-The aim of this study was to assess the criterion validity, interunit reliability (accounting for technological and biological variance), and between-day reliability of a novel optic laser device (FLEX) for quantifying mean concentric velocity. To assess the validity against a three-dimensional motion capture system and interunit reliability with both technological and biological variation, 18 men and women completed repetitions at 20, 40, 60, 80, 90, and 100% of one repetition maximum in the free-weight barbell back squat and bench press. To assess interunit (technological only) reliability, a purpose-built, calibrated rig completed a set protocol with 2 devices. To assess between-day reliability of the technology, the same protocol was repeated 21 days later. Standardized bias, typical error of the estimate (TEE; %), and Pearson's correlation coefficient (r) were used to assess validity, whereas typical error and coefficient of variation (CV%) were calculated for reliability. Overall, TEE (±90 CL) between the FLEX and criterion measure was 0.03 (±0.004) and 0.04 (±0.005) m·s in the back squat and bench press, respectively. For measures of reliability, overall interunit technological variance (CV% [± 90% confidence interval]) was 3.96% (3.83-4.12) but increased to 9.82% (9.31-10.41) and 9.83% (9.17-10.61) in the back squat and bench press, respectively, when biological variance was introduced. Finally, the overall between-day reliability was 3.77% (3.63-3.91). These findings demonstrate that the FLEX provides valid and reliable mean concentric velocity outputs across a range of velocities. Thus, practitioners can confidently implement this device for the monitoring and prescription of resistance training loads.
More Related Videos
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
07:30Muscle Imbalances: Testing and Training Functional Eccentric Hamstring Strength in Athletic Populations
Published on: May 1, 2018
Related Concept Videos
Reliability and Validity
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Measurement of Blood Pressure
Exercise and Muscle Performance
Endurance exercises
Endurance exercises involve running, swimming, or cycling, which require repetitive movements with low force output. When a person engages in endurance exercise, a few noticeable changes occur in their skeletal muscles. For instance, the number of capillaries...