Related Experiment Video
Updated: Dec 20, 2025

An Improved Mechanical Testing Method to Assess Bone-implant Anchorage
Published on: February 10, 2014
Practice-Based Clinical Evaluation of Dental Implants Placed with Immediate or Delayed Loading Protocols: One-Year
Adolfo Coelho de Oliveira Lopes1, Paulo Guilherme Coelho2, Paulo Sérgio Perri de Carvalho de Carvalho3
1Department of Prosthodontics and Periodontology, University of São Paulo, Bauru School of Dentistry, Bauru, SP, Brazil, 17.012-901.
Abstract:
We evaluate bone remodeling and prostheses survival of immediately provisionalized with occlusal loading and delayed loading (DL) single implants placed in the posterior region after 1-yr follow-up in dental practices. Included in the study are patients selected to receive one regular implant (4 × 10 mm) for single tooth replacement in healed ridge sockets in the mandible and maxilla. Implants are immediately loaded or delayed functionally loaded with metal ceramic crowns, depending on peak insertion torque value. All implants are clinically and radiographically evaluated at T1, immediately postoperatively; T2, 60 d; T3, 180 d; and T4, 360 d. Measurements between implant platform and top of alveolar bone crest at distal and mesial areas are performed using periapical radiographs. Data are statistically evaluated through two-way repeated measures of analysis of variance following post hoc comparisons using the Tukey test (p < 0.05). Ten specialists working in ten different practices treat 36 patients who receive one implant each with internal conical connection (hybrid implant system, 4 × 10 mm) (Emfils; Itu, Brazil). Results show that bone-level alterations in immediate (IM; 0.56 mm; confidence interval [CI]: ± 0.21 mm) and delayed (0.65 mm; CI: ± 0.19 mm) groups are not significantly different (p = 0.515) during the course of the 1-yr observation period. In both groups, statistically significant progressive bone-level remodeling occurs through the evaluated follow-up time points (p < 0.047). All prostheses are rated "alpha," presenting 100% success at 1-yr follow-up. The loading method does not influence bone-remodeling levels around IM or DL at the posterior region after 1-yr follow-up. No prostheses complications are reported.
More Related Videos
05:54Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021
06:36Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness
Published on: March 14, 2025