Mirror symmetric broadband homodecoupled perfect echo spectroscopy
Peyman Sakhaii1, Bojan Bohorc1, Uwe Schliedermann1
1NMR Laboratory of SANOFI, TIDES Analytical Sciences / German NMR Platform Industriepark Hoechst, Building G849, D-65926 Frankfurt/Main, Germany.
Abstract:
A new experiment for recording phase sensitive ω1-broadband homodecoupled TOCSY spectra is presented. The method is an extension of the already existing perfect echo (PE) filter, proposed to sample t1 chemical shift under sustained homodecoupling. The modification is made by attaching a time reversed perfect echo filter to a regular perfect echo scheme. Thus it becomes possible to acquire for longer t1 acquisition times without compromising the quality of homodecoupling. The mirror symmetric double perfect echo is implemented into the evolution period of a TOCSY experiment. A spin lock pulse purges undesired dispersive antiphase components at the end of the central t1 evolution period. Pure absorptive lineshapes with reduced proton spin multiplicities are obtained. The approach can be used in conjunction with real or constant time chemical shift evolution. In case of compounds with reduced T2 relaxation time, the real time approach is advisable, where the echo delays are an extension of the t1 evolution period. In this way, an unnecessary loss due to T2 relaxation is avoided. Using the pulse sequence in constant time mode at high t1max values gives ω1-homodecoupled TOCSY spectra without a significant dependence of the transfer amplitude on J. All experiments were carried out using non uniform sampling to decrease the measurement time. Experimental setup, advantages and limitations are discussed.
Related Concept Videos
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations
2D NMR: Homonuclear Correlation Spectroscopy (COSY)
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....