Related Experiment Video
Updated: Dec 20, 2025

Synchrotron X-ray Microdiffraction and Fluorescence Imaging of Mineral and Rock Samples
Published on: June 19, 2018
Elemental Distribution in Animal Carpal and Tarsal Bones Using Differences in X-ray Fluorescence Energy
Tanita Pitakarnnop1,2, Kittisak Buddhachat3,4, Pongpitsanu Pakdeenarong1
1Forensic Science and Criminal Justice, Faculty of Science, Silpakorn University, Nakhon Pathom, 73000, Thailand.
Abstract:
Little is known as to whether different operating voltages of X-ray fluorescence (XRF) can affect the accuracy rate for species identification. Here, we have addressed this question by comparing the rate of correct species identification using the elemental composition of either the carpal or tarsal bone obtained from a determination of the different energy values of XRF at 15 and 50 kV using energy-dispersive XRF (ED-XRF). Carpal bones were taken from 16 species and tarsal bones from 11 of these species. The data on the elemental profiles were analyzed by stepwise discriminant analysis for species discrimination. The classification results indicated that 94.1% and 63.7% of the originally grouped cases were correctly classified as carpal bones using 15 kV and 50 kV, respectively. Additionally, 69.4% and 77.3% of the originally grouped cases were correctly classified as tarsal bones using 15 kV and 50 kV, respectively. When the datasets of the elemental profiles obtained using two operating voltages were gathered, the classification results of the prediction rate appeared to be more accurate at 89.7% and 90.7% in the carpal and tarsal bones, respectively. In conclusion, our findings suggest that the elemental profiles of bones obtained using two operating voltages could effectively facilitate accurate species discrimination.
More Related Videos
10:06Characterization Of Multi-layered Fish Scales Atractosteus spatula Using Nanoindentation, X-ray CT, FTIR, and SEM
Published on: July 10, 2014
14:55Analysis of Minerals Produced by hFOB 1.19 and Saos-2 Cells Using Transmission Electron Microscopy with Energy Dispersive X-ray Microanalysis
Published on: June 24, 2018
Related Concept Videos
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
Atomic Emission Spectroscopy: Overview
Scanning Electron Microscopy
Fundamental Principles
Accelerated...
Atomic Emission Spectroscopy: Lab
Atomic Spectroscopy: Absorption, Emission, and Fluorescence
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...