Mitochondrial energetics and contents evaluated by flow cytometry in human maternal and umbilical cord blood
Julie Kristine Guldberg Stryhn1,2,3, Jacob Larsen2,4, Palle Lyngsie Pedersen2,5
1Department of Gynecology and Obstetrics, Slagelse Hospital, Slagelse, Denmark.
Abstract:
Background: Mitochondrial dysfunction may relate to metabolic disorders. The relation between maternal and fetal mitochondrial function needs attention due to heritage.Objectives: To evaluate the use of the staining methods TetraMethylRhodamine Methyl Ester (TMRM) and Mitotracker Green (MTG) for flow cytometric measurements of umbilical cord blood mitochondrial function. Methods 53 euthyroid at-term pregnant women and their offspring were included by blood collections. The offspring had blood drawn from the clamped umbilical cord. Flow cytometry with MTG, TMRM and Propidium Iodide were performed the following day. A cell count (antibody coating and flow cytometry) was performed for 9 maternal and cord samples. As a quality control, blood of 32 healthy donors was evaluated by flow cytometric analyzes same day as sampling and the following day to test stability of the measurements.Results: Cord mitochondrial measurements were lower than maternal. Maternal and cord mitochondrial function were positively correlated, especially reflected by MTG fluorescence-intensity (FI). Samples stored presented with very changed fluorescence patterns. However, the fluorescence intensity ratios MTG/TMRM of stained white blood cells were related within same day measurements, depicting an extensive and common bioenergetic cellular change.Conclusion: Cord blood flow cytometry by MTG- and TMRM- staining is possible with fluorescence intensity positively correlated to maternal fluorescence intensity. Storage of blood triggers mitochondrial dynamics. The methods are applicable with certain reservations, and they benefit from their non-invasive character compared to mitochondrial evaluation by muscle-biopsies.
More Related Videos
07:57Measurement of Mitochondrial Mass and Membrane Potential in Hematopoietic Stem Cells and T-cells by Flow Cytometry
Published on: December 26, 2019
08:04Measuring Mitochondrial Electron Transfer Complexes in Previously Frozen Cardiac Tissue from the Offspring of Sow: A Model to Assess Exercise-Induced Mitochondrial Bioenergetics Changes
Published on: August 16, 2021