Related Experiment Video
Updated: Dec 20, 2025

10:10
Reverse Total Shoulder Arthroplasty
Published on: July 5, 2011
43.7K
Revision arthroplasty with rotating hinge systems for total knee arthroplasty instability
Jörg Arnholdt1, Sebastian Philipp Boelch2, Fatma Dogan2
1Department of Orthopaedic Surgery, Orthopädische Klinik König-Ludwig-Haus, Julius-Maximilians-University Würzburg, Brettreichstr. 11, 97074, Würzburg, Germany. j-arnholdt.klh@uni-wuerzburg.de.
Operative Orthopadie Und Traumatologie
|May 31, 2020
Summary
This study shows a cemented rotating hinge system effectively restores stability and function after total knee arthroplasty (TKA) revisions. Patients experienced significant improvements in knee scores and pain relief, demonstrating the system
Area of Science:
- Orthopaedic surgery
- Biomedical engineering
- Reconstructive surgery
Background:
- Total knee arthroplasty (TKA) can result in ligament instability and osseous defects.
- Revision TKA is complex, often requiring specialized implant systems.
- Existing TKA may fail due to instability or bone loss, necessitating revision surgery.
Purpose of the Study:
- To evaluate the efficacy of a cemented rotating hinge system for TKA revision.
- To restore stability and improve joint function in patients with complex knee instability post-TKA.
- To assess functional outcomes and pain reduction following revision with this specific implant system.
Main Methods:
- Prospective study of 18 patients undergoing TKA revision with a cemented rotating hinge system.
- Included patients with ligament insufficiency and/or Anderson Orthopaedic Research Institute (AORI) type II defects.
- Surgical technique involved component removal, debridement, joint line reconstruction, and cement fixation.
Main Results:
- Significant improvement in Oxford Knee Score (OKS) from 19 to 29 (p=0.004).
- Significant improvement in Knee Society Score (KSS) knee assessment from 35 to 67 (p=0.002).
- Significant reduction in pain scores from 7 to 24 (p=0.008) at a mean 37-month follow-up.
Conclusions:
- The cemented rotating hinge system provides a viable solution for TKA revision in cases of ligament instability.
- This system significantly enhances functional outcomes, including range of motion and pain relief.
- The study supports the use of this specialized implant for complex TKA revisions.