Related Experiment Video
Updated: Dec 20, 2025

Magnetic Resonance Derived Myocardial Strain Assessment Using Feature Tracking
Published on: February 12, 2011
Influence of contrast agent and spatial resolution on myocardial strain results using feature tracking MRI
Florian von Knobelsdorff-Brenkenhoff1, Tobias Schunke2, Stephanie Reiter2
1Department of Cardiology, Clinic Agatharied, Ludwig-Maximilians-University of Munich, Norbert-Kerkel-Platz, Hausham, Agatharied, 83734, Munich, Germany. florian.vonknobelsdorff@khagatharied.de.
Objectives:
Feature tracking for assessing myocardial strain from cardiac magnetic resonance (CMR) cine images detects myocardial deformation abnormalities with prognostic implication, e.g., in myocardial infarction and cardiomyopathy. Standards for image acquisition and processing are not yet available. Study aim was analyzing the influence of spatial resolution and contrast agent on myocardial strain results.
Methods:
Seventy-five patients underwent CMR for analyzing peak systolic circumferential, longitudinal, and radial strain. Group A included n = 50 with normal left ventricular ejection fraction, no wall motion abnormality, and no fibrosis on late enhancement imaging. Group B included n = 25 with chronic myocardial infarct. For feature tracking, steady-state free precession cine images were acquired repeatedly. (1) Native standard cine (spatial resolution 1.4 × 1.4 × 8 mm3). (2) Native cine with lower spatial resolution (2.0 × 2.0 × 8 mm3). (3) Cine equal to variant 1 acquired after administration of gadoteracid.
Results:
Lower spatial resolution was associated with elevated longitudinal strain (- 21.7% vs. - 19.8%; p < 0.001) in viable myocardium in group A, and with elevated longitudinal (- 17.0% vs. - 14.3%; p = 0.001), circumferential (- 18.6% vs. - 14.6%; p = 0.002), and radial strain (36.8% vs. 31.0%; p = 0.013) in infarcted myocardium in group B. Gadolinium administration was associated with reduced circumferential (- 21.4% vs. - 22.3%; p = 0.001) and radial strain (44.4% vs. 46.9%; p = 0.016) in group A, whereas strain results of the infarcted tissue in group B did not change after contrast agent administration.
Conclusions:
Variations in spatial resolution and the administration of contrast agent may influence myocardial strain results in viable and partly in infarcted myocardium. Standardized image acquisition seems important for CMR feature tracking.
Key Points:
• Feature tracking is used for calculating myocardial strain from cardiac magnetic resonance (CMR) cine images. • This prospective study demonstrated that CMR strain results may be influenced by spatial resolution and by the administration of gadolinium-based contrast agent. • The results underline the need for standardized image acquisition for CMR strain analysis, with constant imaging parameters and without contrast agent.
More Related Videos
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
11:13Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies IV: Magnetic Resonance Imaging
Magnetic Resonance Imaging