Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Maxwell-Boltzmann Distribution: Problem Solving01:20

Maxwell-Boltzmann Distribution: Problem Solving

2.7K
Individual molecules in a gas move in random directions, but a gas containing numerous molecules has a predictable distribution of molecular speeds, which is known as the Maxwell-Boltzmann distribution, f(v).
This distribution function f(v) is defined by saying that the expected number N (v1,v2) of particles with speeds between v1 and v2 is given by
2.7K
Distance Corrections01:15

Distance Corrections

221
To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
221
Propagation of Uncertainty from Systematic Error01:10

Propagation of Uncertainty from Systematic Error

1.2K
The atomic mass of an element varies due to the relative ratio of its isotopes. A sample's relative proportion of oxygen isotopes influences its average atomic mass. For instance, if we were to measure the atomic mass of oxygen from a sample, the mass would be a weighted average of the isotopic masses of oxygen in that sample. Since a single sample is not likely to perfectly reflect the true atomic mass of oxygen for all the molecules of oxygen on Earth, the mass we obtain from this...
1.2K
Propagation of Uncertainty from Random Error00:59

Propagation of Uncertainty from Random Error

1.6K
An experiment often consists of more than a single step. In this case, measurements at each step give rise to uncertainty. Because the measurements occur in successive steps, the uncertainty in one step necessarily contributes to that in the subsequent step. As we perform statistical analysis on these types of experiments, we must learn to account for the propagation of uncertainty from one step to the next. The propagation of uncertainty depends on the type of arithmetic operation performed on...
1.6K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Gastrointestinal Motility-Induced Interplay in Pancreas Proton Therapy: Motion Simulation and Dosimetric Impact.

International journal of radiation oncology, biology, physics·2026
Same author

[A Transformer-based multimodal model for predicting hospital-acquired infections using imaging and clinical laboratory data].

Nan fang yi ke da xue xue bao = Journal of Southern Medical University·2026
Same author

A Neural-Analytical Fusion Scatter Correction Method for Multi-Source CT Using Equivalent High-Order Scatter.

IEEE transactions on medical imaging·2026
Same author

FLASH radiotherapy preserves hepatic function and maintains metabolic homeostasis in a murine breast cancer model: an experimental preclinical study.

Radiation oncology (London, England)·2026
Same author

Integrated tumor habitat and metabolic hot spot displacement analysis on [¹⁸F]FDG PET/CT for predicting treatment response and progression in unresectable locally advanced NSCLC: a two-center competing risk study.

European journal of nuclear medicine and molecular imaging·2026
Same author

Proton FLASH preserves neurocognition across delivery techniques: implications for clinical translation in pediatric brain tumors.

bioRxiv : the preprint server for biology·2026
Same journal

Accounting for approximation errors using surrogate-based parameter estimation of cardiac mechanics digital twins.

Computer methods and programs in biomedicine·2026
Same journal

Facial iPPG heatmap patterns based on period-aware autoencoder show association with carotid atherosclerosis towards non-contact hemodynamic assessment.

Computer methods and programs in biomedicine·2026
Same journal

Explainable machine learning models predict liver fibrosis risk and outcome in the general population: Development and multi-cohort external validation.

Computer methods and programs in biomedicine·2026
Same journal

Evaluation of surrogate endpoints for survival outcomes using the surrogate package in R.

Computer methods and programs in biomedicine·2026
Same journal

Relative spectral and frication-based descriptors as numerical indicators of place of articulation shifts in fricatives produced by Polish children.

Computer methods and programs in biomedicine·2026
Same journal

Leaflet resection improves valve expansion and hemodynamic performance in redo TAVI with balloon- and self-expanding transcatheter heart valve configurations.

Computer methods and programs in biomedicine·2026
See all related articles

Related Experiment Video

Updated: Dec 20, 2025

Transmission of Multiple Signals through an Optical Fiber Using Wavefront Shaping
09:43

Transmission of Multiple Signals through an Optical Fiber Using Wavefront Shaping

Published on: March 20, 2017

10.2K

Scatter correction based on adaptive photon path-based Monte Carlo simulation method in Multi-GPU platform.

Yangmei Zhang1, Yusi Chen1, Anni Zhong1

  • 1School of Biomedical Engineering, Southern Medical University, Guangzhou, China, 510515.

Computer Methods and Programs in Biomedicine
|May 31, 2020
PubMed
Summary
This summary is machine-generated.

This study introduces a fast GPU-based Metropolis Monte Carlo (MC) method for Cone-beam CT (CBCT) scatter correction. The new gMMC approach significantly improves image quality and reduces artifacts, achieving clinical efficiency.

Keywords:
Cone-beam CTFast Monte CarloGPUImage reconstructionScatter correction

More Related Videos

Controlled Synthesis and Fluorescence Tracking of Highly Uniform PolyN-isopropylacrylamide Microgels
11:34

Controlled Synthesis and Fluorescence Tracking of Highly Uniform PolyN-isopropylacrylamide Microgels

Published on: September 8, 2016

10.7K
Sample Drift Correction Following 4D Confocal Time-lapse Imaging
10:04

Sample Drift Correction Following 4D Confocal Time-lapse Imaging

Published on: April 12, 2014

16.9K

Related Experiment Videos

Last Updated: Dec 20, 2025

Transmission of Multiple Signals through an Optical Fiber Using Wavefront Shaping
09:43

Transmission of Multiple Signals through an Optical Fiber Using Wavefront Shaping

Published on: March 20, 2017

10.2K
Controlled Synthesis and Fluorescence Tracking of Highly Uniform PolyN-isopropylacrylamide Microgels
11:34

Controlled Synthesis and Fluorescence Tracking of Highly Uniform PolyN-isopropylacrylamide Microgels

Published on: September 8, 2016

10.7K
Sample Drift Correction Following 4D Confocal Time-lapse Imaging
10:04

Sample Drift Correction Following 4D Confocal Time-lapse Imaging

Published on: April 12, 2014

16.9K

Area of Science:

  • Medical Imaging
  • Computational Physics
  • Radiotherapy Physics

Background:

  • Monte Carlo (MC) simulations offer precise scatter correction in Cone-beam CT (CBCT) but suffer from low efficiency.
  • Traditional MC methods are computationally expensive due to inefficient particle transport and lack of path control.

Purpose of the Study:

  • To develop and validate an efficient GPU-based Metropolis MC (gMMC) method for rapid scatter correction in CBCT.
  • To improve CBCT image quality by reducing scatter artifacts and enhancing contrast.

Main Methods:

  • Utilized a GPU-based Metropolis MC (gMMC) algorithm for path-by-path sampling to accelerate scatter signal estimation.
  • Integrated planning CT images as prior information for scatter estimation.
  • Applied scatter signal removal from CBCT projections followed by FDK reconstruction.
  • Incorporated accelerating strategies: reduced photon history, pixel/projection angle sampling, and image down-sampling.
  • Implemented the workflow on a 4-GPU workstation for high computational efficiency.

Main Results:

  • The gMMC method significantly reduced image errors (e.g., average error from 21 HU to 7 HU in full-fan).
  • Scatter artifacts were effectively eliminated, leading to improved image contrast.
  • Achieved high computational efficiency with MC simulation times under 2.5 seconds and total workflow times under 15 seconds.

Conclusions:

  • The proposed gMMC method provides a highly efficient and accurate solution for scatter correction in CBCT.
  • This approach enables fast, adaptive CBCT image reconstruction suitable for clinical applications.
  • The method demonstrates feasibility across simulation, phantom, and patient data, with substantial improvements in image quality and speed.