Related Experiment Video
Updated: Dec 20, 2025

Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
Published on: August 8, 2025
Scoring System Assessment of Cephalic Vein Access for Device Implantation
Jane Taleski1, Lidija Poposka1, Filip Janusevski1
1Department of Electrostimulation and Electrophysiology, University Clinic of Cardiology, Skopje, R. Macedonia.
Abstract:
The purpose of this study was to explore the usability of the cephalic vein (CV) for cardiac implantable electronic device (CIED) lead access by applying a scoring system to assess the venous anatomy. This prospective, single-center study included 100 consecutive patients who underwent CIED implantation within a period of one year. Contrast-enhanced venography images were obtained for every patient, focused on the CV, "T-junction," and the subclavian/axillary veins (SV/AVs). Though careful examination of the images, an angle, valves, diameter, noncollateral (AVDnC) score was constructed and used to aid in choosing a CV or SV/AV access approach; in all cases, however, the preferred approach was CV independent of the AVDnC score result obtained. Upon use of the scoring system, the majority of patients (54%) had type A score result (≥ 3), indicating a favorable anatomy for CV access. In 48 of these patients, the CV was used for the implantation of at least one lead. The remaining 46 (46%) patients had type B score result (≤ 2). In 41 patients from this group, SV/AV access was used for lead implantation and, in five patients, CV access was used. The number of leads introduced through the CV was associated with larger score and the operator's experience. In conclusion, in more than 50% of patients, at least one lead could be introduced through the CV. The scoring system used herein can simplify the choice between CV and SV/AV access and could eventually increase the efficiency and safety of the procedure, especially when less experienced implanters are involved.
More Related Videos
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization IV: Nursing Management

