Related Experiment Video
Updated: Dec 20, 2025

Use of Rabbit Eyes in Pharmacokinetic Studies of Intraocular Drugs
Published on: July 23, 2016
Modified insertion technique for a sustained-release dexamethasone intravitreal implant (Ozurdex®)
Daniel H Lee1, Clement K Chan2,3
1Department of Internal Medicine, Mayo Clinic, 13400, E. Shea Blvd., Scottsdale, AZ, USA.
Purpose:
We describe a modified injection technique that adheres a sustained-release dexamethasone intravitreal implant (Ozurdex®) to the vitreous base.
Observations:
This modified technique was applied after removal of a prior dislocated Ozurdex® that migrated into the anterior chamber in one patient, and also on another patient bothered by perception of a large floater induced by a free-floating Ozurdex® in the vitreous cavity previously inserted with the conventional technique. The main feature of this new technique consisted of altering the conventional "bevel-up" orientation of the insertion needle tip towards the vitreous cavity to the modified "bevel-down" orientation of the needle tip directed towards the pars plana and vitreous base, for the purpose of adhering a portion of or the entire dexamethasone implant to the vitreous base. Neither patient developed postoperative complications with this technique.
Conclusions And Importance:
This modified insertion technique allows adherence of Ozurdex® to the vitreous base and avoids adverse effects associated with a free-floating Ozurdex®, such as its migration into the anterior chamber, or visual disturbance associated with movement of the implant.
More Related Videos
07:49Slow-release Drug Delivery through Elvax 40W to the Rat Retina: Implications for the Treatment of Chronic Conditions
Published on: September 17, 2014
06:19Author Spotlight: A Novel Protocol for Intracameral Injections to Enhance Precision in Rodent Ophthalmology
Published on: May 31, 2024