Related Experiment Video
Updated: Dec 20, 2025

A Detailed Protocol for Perspiration Monitoring Using a Novel, Small, Wireless Device
Published on: November 24, 2016
Validity of a wearable sweat rate monitor and routine sweat analysis techniques using heat acclimation
Rebecca Relf1, Gregor Eichhorn1, Kirsty Waldock2
1Environmental Extremes Laboratory, University of Brighton, Eastbourne, BN20 7SR, UK.
Introduction:
the aim of this study was to assess the validity of a novel wearable sweat rate monitor against an array of sweat analysis techniques which determine sudomotor function when exercising moderately under heat stress. Construct validity was determined utilising a 5-day short-term heat acclimation (STHA) intervention.
Methods:
Nineteen healthy individuals (age: 41 ± 23 years, body mass: 74.0 ± 12.2 kg, height: 174.9 ± 6.9 cm) [male; n = 15, female; n = 4] completed nine trials over a three-week period, in a controlled chamber set to 35 °C, 50% relative humidity for all sessions. The pre and post-trials were separated by five consecutive controlled hyperthermia HA sessions. Sweat analysis was compared from pre and post-trial, whereby whole body sweat rate (WBSR) was assessed via pre and post nude body mass. Local sweat rate (LSR) was determined via technical absorbent patches (TA) (weighed pre and post) and a novel wearable KuduSmart® (SMART) monitor which was placed on the left arm during the 30-min of exercise. Tegaderm patches, used to measure sweat sodium chloride conductivity (SC), and TA patches were placed on the back, chest and forearm for the 30-min cycling.
Results:
Sudomotor function significantly adapted via STHA (p < 0.05); demonstrated by a WBSR increase of 24%, LSR increase via the TA method (back: 26%, chest: 45% and arm: 48%) and LSR increase by the SMART monitor (35%). Finally, SC decreased (back: -21%, chest: -25% and arm: -24%, p < 0.05).
Conclusion:
All sweat techniques were sensitive to sudomotor function adaptation following STHA, reinforcing their validity. The real time data given by the wearable KuduSmart® monitor provides coaches and athletes instant comparable sudomotor function feedback to traditional routinely used sweat analysis techniques.
More Related Videos
08:22Using an Ingestible Telemetric Temperature Pill to Assess Gastrointestinal Temperature During Exercise
Published on: October 7, 2015
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Related Concept Videos
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...