Related Experiment Videos
Core and peripheral site measurement of body temperature in short wool sheep
Tellisa R Kearton1, Amanda K Doughty1, Christine L Morton2
1University of New England, Armidale, New South Wales, 2351, Australia; CRC for Sheep Industry Innovation, Armidale, NSW, 2350, Australia.
Abstract:
Understanding circadian rhythms of body temperature is important for the interpretation of single body temperature measurements and the assessment of the physiological state of an animal. The ability to measure body temperature at peripheral locations may also be important in the development of minimally invasive tools for remote temperature measurement in livestock. This study aimed to investigate how well body temperature measured at peripheral sites reflected a commonly used core measurement (vaginal temperature) and the circadian rhythmicity of the body temperature of sheep with a view to practical application in extensive sheep production systems. Eleven crossbred ewes were implanted with peripheral temperature sensing microchips (LifeChip®) which were positioned transversely in the sternocleidomastoid (neck) muscle and subcutaneously under the tail. iButton® temperature loggers were placed intravaginally to record core body temperature measurements (Tv). The body temperature measurements observed at the peripheral sites in the neck (Tn) and tail (Tt) differed significantly to those measured at the core site, Tv (P < 0.05), with Tn lower than Tv and Tt lower than both Tv and Tn. Similarities in circadian rhythm patterns were observed across the day between Tv, Tn and Tt in repeated measures analysis, with a short period of difference between Tv and Tn (from 1400 to 1600 h) and a long period of difference between Tv and Tt (from 1000 to 2100 h) (P < 0.05). These results suggest that neck muscle temperature measurements may have utility in detecting circadian rhythm patterns in core temperature in sheep, but may not accurately reflect absolute core temperatures. Peripheral measures may require adjustment or correction to more accurately reflect absolute core temperature with respect to determining accurate clinical thresholds relative to the expected normal temperature for the time of day observed. Further investigation into the utility and application of peripheral measurement of body temperature is warranted.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...