Related Experiment Video
Updated: Dec 20, 2025

The Calibration and Use of Capacitance Sensors to Monitor Stem Water Content in Trees
Published on: December 27, 2017
External heat-pulse method allows comparative sapflow measurements in diverse functional types in a
Robert P Skelton1, Adam G West1, Todd E Dawson2
1University of Cape Town - Botany, HW Pearson Building Upper Campus, Cape Town, Western Cape 7700, South Africa.
Abstract:
There has been limited application of sapflow technology to small-stemmed species and across co-existing functional types, restricting its use in diverse floras such as the Mediterranean-type shrubland in South Africa. Our main objective was to test whether sapflow may provide an alternative to traditional gas-exchange measurements, which would permit comparative evaluation of transpiration at a previously unattained temporal resolution. We tested miniature external heat ratio method (HRM) sapflow gauges on three co-occurring functional types with contrasting stem or culm anatomies and examined the relationship between sapflow and shoot- and leaf-level water loss in both a controlled and field environment. Our sapflow gauges captured dynamic patterns of transpiration in both settings for all three functional types. In a controlled environment the relationship between sapflow and transpiration was linear in all three species with r2 values ranging from 0.78 for Cannomois congesta Mast. (Restionaceae) to 0.96 for Protea repens (L.) L. (Proteaceae) and Erica monsoniana L.f. (Ericaceae). In the field, r2 values were lower, ranging from 0.59 for C. congesta to 0.74 for P. repens. We discuss the efficacy and potential of this methodology to cast light on patterns of community ecology in functionally diverse shrublands by capturing continuous variation in transpiration.
More Related Videos
08:41A Rapid Laser Probing Method Facilitates the Non-invasive and Contact-free Determination of Leaf Thermal Properties
Published on: January 7, 2017
12:11Measurement of Leaf Hydraulic Conductance and Stomatal Conductance and Their Responses to Irradiance and Dehydration Using the Evaporative Flux Method EFM
Published on: December 31, 2012
Related Concept Videos
Adaptations that Reduce Water Loss
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Responses to Heat and Cold Stress
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...