Related Experiment Video
Updated: Dec 20, 2025

Magnetic Resonance Imaging Quantification of Pulmonary Perfusion using Calibrated Arterial Spin Labeling
Published on: May 30, 2011
Nasopharyngeal carcinoma perfusion MRI: Comparison of arterial spin labeling and dynamic contrast-enhanced MRI
Bohan Xiao1, Peiguo Wang2, Yingru Zhao1
1Department of Radiology.
Abstract:
To investigate the feasibility of 3D arterial spin labeling (ASL) as an alternative to dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) for the qualitative and quantitative evaluation of nasopharyngeal carcinoma (NPC) perfusion.Fifty-two newly diagnosed NPC patients underwent 3D ASL and DCE-MRI scans on a 3.0-T MRI system. The visual qualitative evaluation of the NPC perfusion level was scored from 0 to 3 (0 = no contrast to normal peripheral soft tissue, 3 = pronounced contrast to normal peripheral soft tissue). The visual evaluation of the NPC outline was scored from 0 to 2 (0 = very vague outline, 2 = clear outline). Comparisons of the ASL-derived blood flow (BF) with the DCE-MRI-derived positive enhancement integral, maximum slope of increase, maximum slope of decrease, and time to peak (TTP) were conducted between NPC and non-NPC areas with independent samples t-tests. The diagnostic performance of these parameters was assessed by receiver operating characteristic curve analysis. The correlations between ASL BF and DCE parameters were assessed by Spearman correlation analysis.There was no difference in the visual scores of the NPC perfusion level between the 2 perfusion methods (P= .963). ASL had a lower visual score for describing the outline of NPC than DCE-MRI (P < .001). The ASL and DCE parameters of the NPC areas were significantly different from those of the non-NPC areas (P < .001). The ASL BF showed the largest area under the receiver operating characteristic curve (AUC) of 0.936 for identifying NPC. When all NPC and non-NPC areas were taken into account, significant correlations were observed between the ASL BF and the DCE parameters positive enhancement integral (r = 0.503, P < .001), maximum slope of increase (r = 0.616, P < .001), maximum slope of decrease (r = 0.380, P < .001), and TTP (r = -0.601, P < .001).3D ASL could reveal the hyperperfusion of NPC in a qualitative and quantitative manner without using contrast agent. Additionally, the ASL BF correlated significantly with the semiquantitative DCE-MRI parameters.
More Related Videos
05:23Author Spotlight: Noninvasive Cerebral Blood Flow Determination in Human Functional Brain Region for Diagnosis of Neurological Disorders
Published on: May 31, 2024
06:24Dynamic Contrast Enhanced Magnetic Resonance Imaging of an Orthotopic Pancreatic Cancer Mouse Model
Published on: April 18, 2015
Related Concept Videos
Magnetic Resonance Imaging
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...