Related Experiment Video
Updated: Oct 6, 2026

Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity
Published on: March 7, 2016
Micro QuEChERS-based method for the simultaneous biomonitoring in whole blood of 360 toxicologically relevant
Cristian Rial-Berriel1, Andrea Acosta-Dacal2, Manuel Zumbado3
1Toxicology Unit, Research Institute of Biomedical and Health Sciences (IUIBS), Universidad de Las Palmas de Gran Canaria, Paseo Blas Cabrera s/n, 35016 Las Palmas de Gran Canaria, Spain; Study Group on Wild Animal Conservation Medicine (GEMAS), Spain.
Abstract:
This work presents the optimization, validation, and verification of a miniaturized method for the determination of 360 environmental pollutants that are of toxicological concern for wildlife. The method implies a one-step QuEChERS-based extraction of 250 μl whole blood using acidified acetonitrile, followed by two complementary analyses by LC-MS/MS and GC-MS/MS. The optimized conditions allow the simultaneous determination of the major persistent organic pollutants, a wide range of plant protection products, rodenticides, pharmaceuticals, and a suite of metabolites that can be used as biomarkers of exposure. The method is very sensitive, and 95% of the pollutants can be detected at concentrations below 1.5 ng/ml. The method was applied to a series of 148 samples of nocturnal and diurnal wild raptors collected during field ecological studies in 2018 and 2019. Fifty-one different contaminants were found in these samples, with a median value of 7 contaminants per sample. As expected, five of the six contaminants that were detected in >50% of the samples were persistent or semi-persistent organic pollutants. However, it is striking the high frequency of detection of some non-persistent pollutants, such as 2-phenylphenol, benalaxyl, metaflumizone, diphenylamine, brodifacoum or levamisole, indicating the penetration of these chemicals into the food chains. The toxicological significance of all these findings should be studied in depth in future research. However, the results clearly demonstrated that the approach developed provides reliable, simple, and rapid determination of a wide range of pollutants in wildlife and makes it very useful to obtain valuable data in biomonitoring studies with only small amounts of sample.
More Related Videos
08:14Ecotoxicological Methodologies to Evaluate Biomarkers at Different Scales in Neotropical Anurans
Published on: April 28, 2023
04:39A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025