Evaluation of a Point-of-Care Testing Analyzer for Measuring Peripheral Blood Leukocytes
Published on: March 22, 2022
Comparison of four algorithms on establishing continuous reference intervals for pediatric analytes with
Kun Li1,2, Lixin Hu3, Yaguang Peng2
1Department of Epidemiology and Health Statistics, School of Public Health, Capital Medical University, Beijing, 100069, China.
Background:
Continuous reference intervals (RIs) allow for more precise consideration of the dynamic changes of physiological development, which can provide new strategies for the presentation of laboratory test results. Our study aimed to establish continuous RIs using four different simulation methods so that the applicability of different methods could be further understood.
Methods:
The data of alkaline phosphatase (ALP) and serum creatinine (Cr) were obtained from the Pediatric Reference Interval in China study (PRINCE), in which healthy children aged 0-19 years were recruited. The improved non-parametric method, the radial smoothing method, the General Additive Model for Location Scale and Shape (GAMLSS), and Lambda-Median-Sigma (LMS) were used to develop continuous RIs. The accuracy and goodness of fit of the continuous RIs were evaluated based on the out of range (OOR) and Akaike Information Criterion (AIC) results.
Results:
Samples from 11,517 and 11,544 participants were used to estimate the continuous RIs of ALP and Cr, respectively. Time frames were partitioned to fulfill the following two criteria: sample size = 120 in each subgroup and mean difference = 2 between adjacent time frames. Cubic spline or penalized spline was used for curve smoothing. The RIs estimated by the four methods approximately overlapped. However, more obvious edge effects were shown in the curves fit by the non-parametric methods than the semi-parametric method, which may be attributed to insufficient sample size. The OOR values of all four methods were smaller than 10%.
Conclusions:
All four methods could be used to establish continuous RIs. GAMLSS and LMS are more reliable than the other two methods for dealing with edge effects.
Related Concept Videos
Drug Dosing: Infants and Children
Pharmacokinetics in Pediatric Patients: Drug Excretion
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Pharmacokinetics in Pediatric Patients: Drug Metabolism
Determination of Renal Drug Clearance: Graphical and Midpoint Methods
The graphical method involves plotting the rate of drug excretion in urine against the plasma drug concentration. By analyzing the graph, the clearance can be calculated and obtained. Drugs rapidly excreted by the kidneys exhibit a...
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.