Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Magnetic Field Of A Current Loop01:16

Magnetic Field Of A Current Loop

6.1K
Consider a circular loop with a radius a, that carries a current I. The magnetic field due to the current at an arbitrary point P along the axis of the loop can be calculated using the Biot-Savart law.
6.1K
Magnetic Field Due To A Thin Straight Wire01:28

Magnetic Field Due To A Thin Straight Wire

5.9K
Consider an infinitely long straight wire carrying a current I. The magnetic field at point P at a distance a from the origin can be calculated using the Biot-Savart law.
5.9K
Force On A Current Loop In A Magnetic Field01:17

Force On A Current Loop In A Magnetic Field

3.9K
Magnetic forces on wires carrying current are most frequently applied in motors. A DC motor is a device that converts electrical energy into mechanical work. In motors, wire loops are enclosed in a magnetic field. When current flows through the loops, the magnetic field applies torque, which causes the shaft to rotate. The direction of the current is reversed once the loop's surface area is lined up with the magnetic field, causing a constant torque on the loop. During the process, commutators...
3.9K
Magnetic Field Due to Two Straight Wires01:18

Magnetic Field Due to Two Straight Wires

4.2K
Consider two parallel straight wires carrying a current of 10 A and 20 A in the same direction and separated by a distance of 20 cm. Calculate the magnetic field at a point "P2", midway between the wires. Also, evaluate the magnetic field when the direction of the current is reversed in the second wire.
4.2K
Magnetic Force On Current-Carrying Wires: Example01:22

Magnetic Force On Current-Carrying Wires: Example

2.0K
In a magnetic field, moving charges encounter a force. If a wire contains these moving charges, i.e., if the wire is carrying a current, then a force acts on the wire as well. Consider a pair of flexible leads holding a wire that is 40 cm long and 10 g in weight in a horizontal position. The wire is placed in a constant magnetic field of 0.40 T, as shown in Figure 1(a). Determine the magnitude and direction of the current flowing in the wire needed to remove the tension in the supporting leads.
2.0K
Magnetic Force On A Current-Carrying Conductor01:25

Magnetic Force On A Current-Carrying Conductor

4.7K
Moving charges experience a force in a magnetic field. Since the magnetic fields produced by moving charges are proportional to the current, a conductor carrying a current creates a magnetic field around it.
Consider a compass placed near a current-carrying wire. The wire experiences a force that aligns the needle of the compass tangentially around the wire. Thus, the current-carrying wire produces concentric circular loops of magnetic field. The magnetic field generated by a wire can be...
4.7K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Strain-Driven Altermagnetic Spin-Splitting Effect in RuO<sub>2</sub>.

Nano letters·2026
Same author

Excessive vigorous exercise impairs cognitive function through a muscle-derived mitochondrial pretender.

Cell metabolism·2026
Same author

The influence of peer support on college students' physical exercise: the mediator of control beliefs and subjective experience, and the moderator of intrinsic value.

Frontiers in psychology·2026
Same author

Excessive vigorous exercise impairs cognitive function through a muscle-derived mitochondrial pretender.

Cell metabolism·2025
Same author

Mesenchymal Stem Cell-Mediated Targeted Drug Delivery Systems for Hepatocellular Carcinoma: Current Advances and Future Directions.

Bioengineering (Basel, Switzerland)·2025
Same author

Laparoscopic versus robotic pancreaticoduodenectomy for distal cholangiocarcinoma after learning curves of surgeons: a multicenter propensity score-matched study.

Hepatobiliary surgery and nutrition·2025

Related Experiment Video

Updated: Dec 19, 2025

Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples
07:01

Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples

Published on: June 9, 2016

9.9K

Spin current nano-oscillator (SCNO) as a potential frequency-based, ultra-sensitive magnetic biosensor: a simulation

Renata Saha1, Kai Wu1, Diqing Su2

  • 1Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN 55455, United States of America.

Nanotechnology
|June 4, 2020
PubMed
Summary

This study demonstrates a GHz-frequency ferromagnetic resonance biosensor for detecting magnetic nanoparticles (MNPs). The spin current nano-oscillator (SCNO) biosensor can detect single MNPs with high sensitivity, even with background noise.

More Related Videos

High-Speed Magnetic Tweezers for Nanomechanical Measurements on Force-Sensitive Elements
08:50

High-Speed Magnetic Tweezers for Nanomechanical Measurements on Force-Sensitive Elements

Published on: May 12, 2023

2.6K
Fabrication of Carbon Nanotube High-Frequency Nanoelectronic Biosensor for Sensing in High Ionic Strength Solutions
12:20

Fabrication of Carbon Nanotube High-Frequency Nanoelectronic Biosensor for Sensing in High Ionic Strength Solutions

Published on: July 22, 2013

18.6K

Related Experiment Videos

Last Updated: Dec 19, 2025

Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples
07:01

Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples

Published on: June 9, 2016

9.9K
High-Speed Magnetic Tweezers for Nanomechanical Measurements on Force-Sensitive Elements
08:50

High-Speed Magnetic Tweezers for Nanomechanical Measurements on Force-Sensitive Elements

Published on: May 12, 2023

2.6K
Fabrication of Carbon Nanotube High-Frequency Nanoelectronic Biosensor for Sensing in High Ionic Strength Solutions
12:20

Fabrication of Carbon Nanotube High-Frequency Nanoelectronic Biosensor for Sensing in High Ionic Strength Solutions

Published on: July 22, 2013

18.6K

Area of Science:

  • Spintronics
  • Nanotechnology
  • Biosensing

Background:

  • Ferromagnetic resonances (FMR) are crucial for detecting magnetic nanoparticles (MNPs).
  • Spin current nano-oscillators (SCNOs) offer potential for advanced biosensing applications.
  • Existing biosensors face challenges with sensitivity and background noise interference.

Purpose of the Study:

  • To investigate the feasibility of using SCNOs for GHz-frequency FMR-based detection of MNPs.
  • To analyze the impact of MNP binding on SCNO FMR peaks and resonance shifts.
  • To explore position-sensitivity effects in SCNO biosensors and propose mitigation strategies.

Main Methods:

  • Micromagnetic simulations were employed to model SCNO behavior.
  • The study simulated the interaction between antibody-MNP complexes and the SCNO surface.
  • FMR peak shifts and device performance variations with different MNP sizes were analyzed.

Main Results:

  • SCNOs operating in precession mode exhibit measurable FMR peak shifts upon MNP detection.
  • The biosensor shows position-sensitive behavior, which can be effectively mitigated.
  • Simulations confirm the potential for detecting single MNPs with high sensitivity.

Conclusions:

  • Micromagnetic simulations validate the SCNO as a promising platform for frequency-based nano-biosensing.
  • The proposed SCNO biosensor demonstrates the capability to detect single MNPs amidst background noise.
  • Further research can optimize SCNO design for enhanced biosensing performance and reduced position sensitivity.