Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
Published on: February 21, 2025
Improved Diagnostic Performance of New-generation 320-slice Computed Tomography with Forward-projected Model-based
Hiroyuki Takaoka1, Masae Uehara2, Yuichi Saito1
1Department of Cardiovascular Medicine, Chiba University Graduate School of Medicine, Japan.
Abstract:
Objective Forward-projected Model-based Iterative Reconstruction SoluTion (FIRST) is a novel reconstruction method. We investigated the improvement in the diagnostic performance for the detection of abnormal late enhancement (LE) in left ventricular myocardium (LVM) using a new-generation 320-slice computed tomography (CT) device with FIRST. Methods This is a retrospective study that included 100 adult patients who underwent cardiac CT including a late phase scan and magnetic resonance imaging (MRI) within 3 months. The first 50 consecutive patients (first-generation group) underwent first-generation 320-slice CT without FIRST, and the next 50 consecutive patients (second-generation group) underwent second-generation 320-slice CT with FIRST. We compared the diagnostic performance of the first- and second-generation 320-slice CT with FIRST with MRI as a reference standard to detect LE in LVM. Results In the patient-based analysis, the sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy of detection of LE on CT were 79%, 90%, 92%, 76%, and 84%, respectively, in the first-generation group and 97%, 84%, 91%, 94%, and 92%, respectively, in the second-generation group. The sensitivity was significantly higher in the second-generation group than in the first-generation group (p=0.049). In the segment-based analysis, the sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy of detection of LE on CT were 69%, 96%, 83%, 92%, and 90%, respectively, in the first-generation group and 87%, 94%, 84%, 95%, and 92%, respectively, in the second-generation group. The sensitivity and negative predictive value were significantly higher in the second-generation group than in the first-generation group (p<0.001 and p=0.016). The contrast-noise ratio was significantly higher in the second-generation group than in the first-generation group (5.6±1.7 vs. 2.8±1.1, p<0.001), and the radiation dose for the assessment of LE on CT was significantly higher in the first-generation group than in the second-generation group (4.7±2.7 mSv vs. 2.3±0.1 mSv, p<0.001). Conclusion The diagnostic performance for the detection of LE in LVM significantly improved with the use of second-generation 320-slice CT and FIRST.
More Related Videos
12:15Tissue Preparation Techniques for Contrast-Enhanced Micro Computed Tomography Imaging of Large Mammalian Cardiac Models with Chronic Disease
Published on: February 8, 2022
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography