The Axillary Fossa: An Uncovered Hidden Site as a New Alternative for Cardiac Pacemaker and Defibrillator
Esteban M Kloosterman1,2, Jonathan Rosman1, Murray Rosenbaum1
1Department of Cardiology, Lynn Heart and Vascular Institute, Boca Raton Regional Hospital, Boca Raton, FL, USA.
Abstract:
Inadequate thickness of subcutaneous tissue, pectoralis muscle wasting, and/or a lack of availability of subpectoral space can become significant issues in patients with or requiring cardiovascular implantable electronic devices (CIEDs). This is particularly concerning but not exclusive in the elderly population, who may experience discomfort and hypersensitivity of the site as well as the potential for erosion and an increased risk of infection. Thus, the use of an alternative location, the axillary fossa, offers several advantages that make it a suitable option. Specifically, it usually has a preserved fat pad (even in thin patients); is unperturbed by arm movement; is not directly exposed to contact; is easily accessed with no significant compromise of neurovascular structures; and is near the conventional subclavicular sites, with enough lead length to reach in case of the need for generator replacement. Here, we present a series of five patients, including details of their anatomy and the implant techniques used. Two underwent device replacements, with one of them presenting with significant ongoing site discomfort and the other with extreme tissue thinning, respectively. Two patients with no significant fat layer or pectoral muscle wasting had new pacemakers implanted. Lastly, a biventricular implantable cardioverter-defibrillator generator was reimplanted in a younger patient who had issues with protrusion and discomfort in the setting of thin subcutaneous tissue and the subpectoral space being occupied by a large breast implant. In conclusion, the use of the axillary fossa as a new alternative CIED implantation site, using the proposed implant technique, appears feasible and safe and demonstrated excellent results related to patient comfort and adequate device cover in five cases.
More Related Videos
08:00Reduction of Iatrogenic Atrial Septal Defects with an Anterior and Inferior Transseptal Puncture Site when Operating the Cryoballoon Ablation Catheter
Published on: June 15, 2015
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Cardiopulmonary Resuscitation III: AED Use
Pulse Assessment Sites