Abstract:
Inappropriate sinus tachycardia (IST) is a rare type of arrhythmia that is currently difficult to treat successfully. The effects of laser catheter applications aimed at the sinus nodal area were tested experimentally and the technique was used for the treatment of IST. Continuous-wave, mapping-guided 1,064 nm neodymium-doped yttrium aluminum garnet laser applications at 15 W (9.5 W/mm2) per 15 seconds (142.5 J/mm2) and an irrigation flow of 30 mL/min were aimed at the sinus nodal area in five dogs (three applications each) and one human patient (two applications) by use of an 8-French open-irrigated electrode-laser mapping and ablation (ELMA) catheter provided with three miniature pin electrodes (0.5 mm × 4.0 mm) with interelectrode distances of 2.0 mm arranged symmetrically and radially around the endhole of the catheter tip. Laser application was aimed at the largest and earliest atrial potentials recorded in the focused local electrograms 30 ms to 45 ms prior to the onset of the P-wave in the surface lead electrocardiogram. Lesions were evaluated morphometrically. Holter monitoring in the patient was performed prior to and after treatment. During laser application in the dogs, sinus nodal potential amplitudes dwindled gradually from a mean of 42 mm ± 24 mm to 5.0 mm ± 3.0 mm and sinus cycle lengths lengthened from 452 ms ± 35 ms to 634 ms ± 35 ms (p < 0.0001 for both). In the patient, electrical potential amplitudes in the local electrograms dwindled from 41.0 mm to 5.0 mm and, in the Holter monitor, heart rate decreased from 109 bpm ± 29 bpm to 79 bpm ± 26 bpm (p < 0.0001). IST ablation was painless and without complications. During a follow-up of 4.9 years, the patient was asymptomatic and her heart rate and chronotropic competence remained normal. In conclusion, ablation of IST was achieved by substrate mapping-guided laser application while using the open-irrigated EMLA catheter RytmoLas (LasCor GmbH - Laser Medical Devices, Taufkirchen, Germany). However, this is a proof-of-concept study and further research, preferably in the form of multicenter study trials, is needed for confirmation of the results.
More Related Videos
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
09:13Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures
Published on: April 21, 2013
Related Concept Videos
ECG Interpretation of Arrhythmias I: Sinus Arrhythmias
Types of Arrhythmias
Sinus Node Arrhythmias
Sinus Bradycardia: Originating from the sinoatrial (SA) node, sinus bradycardia involves slower impulses, resulting in a heart rate of less than 60 beats per minute (bpm). Causes include sleep, vagal stimulation, beta-blockers, hypothyroidism,...
Dysrhythmias VI: Management of Dysrhythmias