Related Experiment Video
Updated: Dec 19, 2025

A Large Animal Model for Acute Kidney Injury by Temporary Bilateral Renal Artery Occlusion
Published on: February 2, 2021
Impact of passive heat acclimation on markers of kidney function during heat stress
Nicholas Ravanelli1,2,3, Hadiatou Barry1,2,3, Zachary J Schlader4
1Cardiovascular Prevention and Rehabilitation Centre, Montreal Heart Institute, Montreal, QC, Canada.
New Findings:
What is the central question of this study? Does passive heat acclimation alter glomerular filtration rate and urine-concentrating ability in response to passive heat stress? What is the main finding and its importance? Glomerular filtration rate remained unchanged after passive heat stress, and heat acclimation did not alter this response. However, heat acclimation mitigated the reduction in urine-concentrating ability and reduced the incidence of albuminuria in young healthy adults after passive heat stress. Collectively, these results suggest that passive heat acclimation might improve structural integrity and reduce glomerular permeability during passive heat stress.
Abstract:
Little is known about the effect of heat acclimation on kidney function during heat stress. The purpose of this study was to determine the impact of passive heat stress and subsequent passive heat acclimation on markers of kidney function. Twelve healthy adults (seven men and five women; 26 ± 5 years of age; 72.7 ± 8.6 kg; 172.4 ± 7.5 cm) underwent passive heat stress before and after a 7 day controlled hyperthermia heat acclimation protocol. The impact of passive heat exposure on urine and serum markers of kidney function was evaluated before and after heat acclimation. Glomerular filtration rate, determined from creatinine clearance, was unchanged with passive heat stress before (pre, 133 ± 41 ml min-1 ; post, 127 ± 51 ml min-1 ; P = 0.99) and after (pre, 129 ± 46 ml min-1 ; post, 130 ± 36 ml min-1 ; P = 0.99) heat acclimation. The urine-to-serum osmolality ratio was reduced after passive heating (P < 0.01), but heat acclimation did not alter this response. In comparison to baseline, free water clearance was greater after passive heating before (pre, -0.86 ± 0.67 ml min-1 ; post, 0.40 ± 1.01 ml min-1 ; P < 0.01) but not after (pre, -0.16 ± 0.57 ml min-1 ; post, 0.76 ± 1.2 ml min-1 ; P = 0.11) heat acclimation. Furthermore, passive heating increased the fractional excretion rate of potassium (P < 0.03) but not sodium (P = 0.13) or chloride (P = 0.20). Lastly, heat acclimation reduced the fractional incidence of albuminuria after passive heating (before, 58 ± 51%; after, 8 ± 29%; P = 0.03). Collectively, these results demonstrate that passive heat stress does not alter the glomerular filtration rate. However, heat acclimation might improve urine-concentrating ability and filtration within the glomerulus.
Related Concept Videos
Acute Kidney Injury IV: Diagnostic Studies and Prevention
Acute Kidney Injury III: Clinical Manifestations
Acute Kidney Injury II: Pathophysiology
Acute Kidney Injury I: Introduction
Acute Kidney Injury V: Interprofessional Care
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...

