Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Validation of different stepping counters during treadmill and over ground walking.
Morten Bilde Simonsen1, Mikkel Jacobi Thomsen2, Rogerio Pessoto Hirata2
1Sport sciences, Department of Health Science and Technology, Aalborg University, Fredrik Bajers Vej 7, DK-9220 Aalborg East, Denmark; Centre for Clinical Research, North Denmark Regional Hospital, Bispensgade 37, DK-9800 Hjoerring, Denmark.
Activity tracker step-counting accuracy varies significantly between treadmill tests and real-world field tests. Smartphones demonstrated the highest accuracy across both settings, outperforming other devices in this validation study.
Area of Science:
- Biomedical Engineering
- Wearable Technology
- Sports Science
Background:
- Physical activity trackers are increasingly used in clinical and research settings.
- The expanding market necessitates ongoing validation of these popular devices.
- Existing validation studies often lack real-world field testing.
Purpose of the Study:
- To compare the step-counting validity of activity trackers between treadmill and field test protocols.
- To determine if different activity tracker types exhibit varying accuracy in different testing environments.
Main Methods:
- Thirty healthy adults participated in treadmill tests (2, 3, 4 km/h) and a 982m field test.
- Step counts were video-recorded and compared against four devices: Polar M200, Polar A300, Dunlop pedometer, and a Samsung Galaxy S9 smartphone.
- Validity and agreement were assessed using Bland-Altman plots and Spearman's correlation.
Main Results:
- Field tests showed higher validity than treadmill tests at 4 km/h for all devices.
- The smartphone exhibited the best accuracy, validity, and agreement in both treadmill and field tests.
- Device performance was poor at 2 km/h on the treadmill; only the smartphone performed well at 3 km/h.
Conclusions:
- Step-counting validity differs between treadmill protocols and field tests.
- Future validation studies should incorporate field testing for activity trackers.
- Smartphones offer superior accuracy and lower bias in step-counting validation, particularly in field settings.