Related Experiment Video
Updated: Dec 19, 2025

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Pulse assessment is important with blood pressure measurement in individuals with continuous flow left ventricular
Hernan G Marcos-Abdala1, Ana S Cruz-Solbes1, Imad Hussain1
1Houston Methodist DeBakey Heart & Vascular Center, Houston Methodist Hospital, Houston, TX, USA.
Abstract:
While Doppler and cuff blood pressure techniques are prevalent methods of assessing blood pressure in patients with continuous flow left ventricular assist devices, the impact of pulsatility on measurement is not well established. Retrospective chart analysis of clinical variables including pulse perception, blood pressure (Doppler and standard cuff), and aortic valve opening on echo at clinic visit were abstracted. Stable outpatients on continuous flow left ventricular assist devices support with concomitant portable echo assessment were included. Mean average difference was calculated and Pearson's correlation performed for all those patients who had both Doppler and cuff pressure obtained. In all, 74 Heartmate-II patients with a median time from implant of 380 days were analyzed. A pulse was perceived in 82% of patients with persistent aortic valve opening on portable echo and also in 30% of those who had a persistently closed aortic valve. The mean average difference between the Doppler and systolic cuff pressure was ~13 mmHg (r = 0.5, p = 0.004) when a pulse was present and ~11 mmHg when aortic valve was open (r = 0.68, p < 0.0001). Pulse presence seems to reflect aortic valve opening a majority of the time but not always. In the presence of a prominent pulse or persistent aortic valve opening, the Doppler pressure seems to be more reflective of a systolic pressure than mean perfusion pressure. Hence, assessment of pulsatility needs to be incorporated into blood pressure measurement methods for patients with continuous flow left ventricular assist devices.
More Related Videos
06:10Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
08:49Author Spotlight: Enhancing Graft Viability Assessment Through Quantitative Metrics and Innovative Reservoir Systems
Published on: August 2, 2024
Related Concept Videos
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement