Related Experiment Video
Updated: Dec 19, 2025

Microparticle Manipulation by Standing Surface Acoustic Waves with Dual-frequency Excitations
Published on: August 21, 2018
FEM simulation and comparison of PMN-PT single crystals based phased array ultrasonic transducer by alternating
Zhang Zhang1, Jialin Xu1, Sixing Liu1
1Artificial Crystal Research Center, Shanghai Institute of Ceramics, Chinese Academy of Sciences, 215 Chengbei Road, Jiading, Shanghai 201800, China; University of Chinese Academy of Sciences, Beijing 100049, China.
Abstract:
The Finite element modeling (FEM) simulation and comparison of electroacoustic properties for alternating current poling (ACP) phased arrays and direct current poling (DCP) phased arrays were investigated. The simulated electrical impedance reveals that the effective working bandwidth of ACP phased arrays is wider than that of DCP phased arrays as a whole. Besides, the ACP phased arrays have a higher effective electromechanical coupling coefficient keff compared to DCP arrays, which indicates that higher electromechanical conversion capacity is obtained. The average value of the ratio of longitudinal displacement Rdisp for ACP phased arrays is larger than that of DCP arrays, indicating that the longitudinal transmission efficiency of acoustic energy can be enhanced by using the ACP method. The simulation results of crosstalk are consistent with the results of vibration modal analysis. The coupling effect of transverse vibration for ACP phased arrays is weaker than that of DCP arrays, leading to reduce the interaction between the adjacent elements. The crosstalk of the ACP arrays is -11.87 dB, 0.91 dB lower than that of DCP arrays. The pulse-echo response of ACP phased arrays is 7.2% broader -6 dB bandwidth, 0.79 dB higher relative sensitivity compared to the DCP phased arrays, which prove that the longitudinal resolution and penetration depth of the ultrasonic imaging can be improved by using the ACP arrays. Besides, the consequences of the beam profile illustrate that the maximum acoustic pressure of ACP arrays is 13.8% higher than that of DCP arrays and the directivity of ACP array is slightly better than that of DCP arrays.
More Related Videos
07:44Characterization of Full Set Material Constants and Their Temperature Dependence for Piezoelectric Materials Using Resonant Ultrasound Spectroscopy
Published on: April 27, 2016
16:01An Experimental Protocol for Assessing the Performance of New Ultrasound Probes Based on CMUT Technology in Application to Brain Imaging
Published on: September 24, 2017