Diagnosis of Infective Endocarditis by Subtype Using 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed
Tom Kai Ming Wang1, Alejandro Sánchez-Nadales2, Efehi Igbinomwanhia2
1Section of Cardiovascular Imaging, Robert and Suzanne Tomsich Department of Cardiovascular Medicine, Sydell and Arnold Miller Family Heart, Vascular and Thoracic Institute, Cleveland Clinic, OH (T.K.M.W., P.C., B.G., B.X.).
Abstract:
Background Infective endocarditis (IE) remains a difficult to diagnose condition associated with high mortality. 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) has recently emerged as another IE imaging modality, although diagnostic accuracy varies across observational studies and types of IE. This meta-analysis assessed the diagnostic performance of 18F-FDG PET/CT for IE and its subtypes. Methods We searched Pubmed, Cochrane, and Embase from January 1980 to September 2019 for studies reporting both sensitivity and specificity of 18F-FDG PET/CT for IE. Meta-Disc 1.4 was used to pool data for all cases of IE and its subgroups of native valve IE, prosthetic valve IE, and cardiac implantable electronic devices IE. Results We screened 2566 records from the search, assessed 52 full-text articles, and included 26 studies totaling 1358 patients (509 IE cases). Pooled sensitivity and specificity (95% CI, inconsistency I-square statistic) were 0.74 (0.70-0.77, 71.5%) and 0.88 (0.86-0.91, 78.5%) for all cases of endocarditis. Corresponding parameters for native valve IE were sensitivity 0.31 (0.21-0.41, 29.4%) and specificity 0.98 (0.95-0.99, 34.4%); for prosthetic valve IE: sensitivity 0.86 (0.81-0.89, 60.0%) and specificity 0.84 (0.79-0.88, 75.2%); and for cardiac implantable electronic devices IE: sensitivity 0.72 (0.61-0.81, 76.2%) and specificity 0.83 (0.75-0.89, 83.6%). Pooled sensitivities and specificities were higher for the 17 studies since 2015 than the 9 studies published before 2015. Conclusions 18F-FDG PET/CT had high specificity for all IE subtypes; however, sensitivity was markedly lower for native valve IE than prosthetic valve IE and cardiac implantable electronic devices IE. It is, therefore, a useful adjunct modality for assessing endocarditis, especially in the challenging scenarios of prosthetic valve IE and cardiac implantable electronic devices IE, with improving performance over time, related to advances in 18F-FDG PET/CT techniques.
More Related Videos
Related Concept Videos
Acute Coronary Syndrome III: Diagnostic Studies
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System V: CT
![Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography FDG-PET/CT](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F3777.jpg&w=3840&q=50)