Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
The Validity and Reliability of the Mi Band Wearable Device for Measuring Steps and Heart Rate
Chloe Paradiso1, Franciscio Colino1, Sam Liu1
1School of Exercise Science, Physical & Health Education, University of Victoria, Victoria, BC, CANADA.
Abstract:
The study objectives were to 1) evaluate the criterion validity and reliability of the Mi Band 2 wearable activity monitor to measure steps during a six-minute walk test (6MWT), a treadmill walking test at various speed (1.28 km/h, 1.92 km/h, and 2.88 km/h) and a stair climbing test; 2) assess the validity and reliability of the monitor to measure heart rate during rest and exercise. Fourteen participants (females: n = 8; mean age ± SD: 23 ± 4.2) completed the study. The mean body mass index was 22 ± 3.6. The majority (~92%) of the Mi Band met the standard of 5% absolute percent error for measuring steps during the 6MWT. However, the Mi Band underestimated steps at slower walking speeds (< 2.88 km/h). Mi Band showed good internal consistency during the six-minute walk test and stairs climb (ICC: 0.83). The validity and reliability of the Mi Band to measure heart rate may not be suited for clinical or research use. The Mi Band significantly underestimated heart rate during exercise. Overall, caution is required when interpreting the steps recorded (at slower speeds) and heart rate measurements.
Related Concept Videos
Holter Monitor: 24-Hour Monitoring
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Errors occurring during blood pressure monitoring
Several factors...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring pulse