Related Experiment Video
Updated: Dec 19, 2025

Employing the Forced Oscillation Technique for the Assessment of Respiratory Mechanics in Adults
Published on: February 9, 2022
Changes in spirometric parameters after protective interventions among workers at a chlorine production plant in Iran
Daryoush Pahlevan1, Amir Shomali2, Sara Pooryahya2
1Social Determinants of Health Research Center, Semnan University of Medical Sciences, Semnan, Iran.
Objectives:
This study was conducted to assess changes in spirometric parameters after protective interventions among workers at a chlorine production plant in Semnan, Iran during 2012-2016.
Methods:
This quasi-experimental study included 100 workers at a chlorine production plant in Semnan during 2012-2016. Spirometric parameters (forced vital capacity [FVC], forced expiratory volume in 1 second [FEV1], FEV1/FVC, peak expiratory flow [PEF], and PEF occurring in the middle 50% of the patient's exhaled volume [PEF 25-75%]) were measured in all workers before the initial intervention in 2012. Protective interventions were then implemented for 4 consecutive years and the parameters were measured annually. A multivariable linear regression model was used to assess the factors affecting spirometric parameters before and after the protective interventions in SPSS version 24.
Results:
The mean values of all spirometric parameters significantly increased after the protective interventions (p<0.05). Multivariable linear regression showed that age (β=-0.40), body mass index (BMI) (β=0.71; 95% confidence interval [CI], 0.11 to 1.31), and type of mask (β=-7.88; 95% CI, -15.96 to -0.46) had significant effects on the mean difference in FVC. Similarly, age (β=-0.35; 95% CI, -0.70 to -0.01), BMI (β=0.80; 95% CI, 0.20 to 1.41) and type of mask (β=-8.88; 95% CI, -16.98 to -0.79) had significant associations with the mean difference in FEV1. The type of mask (β=-12.81; 95% CI, -25.01 to -0.60) had a significant effect on the mean difference in PEF.
Conclusions:
All spirometric parameters significantly increased in workers after protective interventions were implemented. Therefore, protective interventions to prevent respiratory disorders in workers exposed to chlorine gas are suggested.
Related Concept Videos
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Chronic Obstructive Pulmonary Disease-I: Introduction
Asthma-I: Introduction
Chronic Obstructive Pulmonary Disease-II: Pathophysiology
Chronic Inflammation
Physical Assessment of the Respiratory Tract I: Health History
Subjective Data
Subjective data provides vital information about the patient's health history and symptoms. This data is typically collected through interviews in which patients describe their experiences, symptoms, and concerns.
Health history and...

