Related Experiment Video
Updated: Dec 19, 2025

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Effect of scan projection radiography coverage on tube current modulation in pediatric and adult chest CT
Kostas Perisinakis1, Nikos Ntoufas2, Mary Velivassaki3
1University of Crete, Medical School, Department of Medical Physics, 71003 Heraklion, Crete, Greece; University Hospital of Heraklion, Department of Medical Physics, P.O. Box 1352, 71110 Heraklion, Crete, Greece.
Purpose:
To investigate the effect of scan projection radiography (SPR) coverage on tube current modulation in pediatric and adult thoracic CT examinations.
Methods:
Sixty pediatric and 60 adult chest CT examinations were retrospectively studied to determine the incidence rate of examinations involving SPRs that did not include the entire image volume (IV) or the entire primarily exposed body volume (PEBV). The routine chest CT acquisition procedure on a modern 64-slice CT system was imitated on five anthropomorphic phantoms of different size. SPRs of varying length were successively acquired. The same IV was prescribed each time and the computed tube current modulation plan was recorded. The SPR boundaries were altered symmetrically by several steps of ±10mm with respect to the IV boundaries.
Results:
The upper IV boundary was found to be excluded from SPR in 52% of pediatric and 40% adult chest CT examinations. The corresponding values for the lower boundary were 15% and 20%, respectively. The computed tube current modulation was found to be considerably affected when the SPR did not encompass the entire IV. SPR deficit of 3cm was found to induce up to 46% increase in the computed tube current value to be applied during the first tube rotations over lung apex.
Conclusions:
The tube current modulation mechanism functions properly only if the IV set by the operator is entirely included in the localizing SPR image. Operators should cautiously set the SPR boundaries to avoid partial exclusion of prescribed IV from SPRs and thus achieve optimum tube current modulation.
More Related Videos
08:34Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
X-ray Imaging