An 18O-Labeling Assisted LC-MS Method for Accurate Quantitation of Unprocessed C-Terminal Lysine in Therapeutic

Shunhai Wang1, Anita P Liu1, Ning Li1

  • 1Analytical Chemistry Group, Regeneron Pharmaceuticals, Inc., 777 Old Saw Mill River Road, Tarrytown, New York 10591-6707, United States.

Unprocessed C-terminal lysine (C-term Lys) is one of the most common causes for the formation of basic variants in therapeutic monoclonal antibodies (mAbs). Although the C-term Lys variants are routinely quantified by a LC-MS-based peptide mapping method using the relative MS responses from both C-terminal peptides (with and without Lys), this approach often leads to overestimation of Lys-containing peptide due to the intrinsic difference in ionization efficiency. Herein, we report an 18O-labeling assisted LC-MS method, which takes advantage of the carboxypeptidase B-catalyzed Lys removal and 18O-labeling to achieve improved accuracy of C-term Lys quantitation. The fidelity of this method was first demonstrated using synthetic peptide mixture standards that mimic a wide range of C-term Lys levels. Finally, the newly developed method was applied in a case study where C-term Lys variants in mAb samples manufactured from different processes were accurately quantified and compared. This new method provides a valuable solution for studies where accurate C-term Lys levels are needed to assist decision-making and root-cause investigation.

Related Concept Videos