Related Experiment Video
Updated: Dec 18, 2025

Efficient Dissection and Culture of Primary Mouse Retinal Pigment Epithelial Cells
Published on: February 10, 2021
A Simple New Technique to Peel Epiretinal Membrane Without Removing Silicone Oil
Kang-Jung Lo1,2, Fenq-Lih Lee1,2, Tai-Chi Lin1,3
1Department of Ophthalmology, Taipei Veterans General Hospital, Taipei, Taiwan.
Purpose:
To introduce a new surgical technique that can keep constant intraocular pressure of the eyeball during peeling epiretinal membrane under silicone oil status.
Methods:
A viscoelastic agent was injected into the air pump of the constellation system via the metal tip. This procedure offers a buffer zone to keep constant pressure within the eyeball without disturbing the surgical field by an air bubble.
Results:
Three cases were performed efficiently (15 ± 5 minutes) under this technique with improvement in anatomical feature and visual function after the surgery.
Conclusion:
Using this simple yet important technique can provide us the constant intraocular pressure without hypotony and avoid the traditional complicated procedures.