Related Experiment Video
Updated: Dec 18, 2025

A Rapidly Incremented Tethered-Swimming Maximal Protocol for Cardiorespiratory Assessment of Swimmers
Published on: January 28, 2020
Effects of the Turbine™ on Ventilatory and Sensory Responses to Incremental Cycling
Michele R Schaeffer, Emily McBride1, Reid A Mitchell
1Life Science Division, Quest University Canada, Squamish, BC, CANADA.
Introduction:
The Turbine™ is a nasal dilator marketed to athletes to increase airflow, which may serve to reduce dyspnea and improve exercise performance, presumably via reductions in the work of breathing (WOB). However, the unpublished data supporting these claims were collected in individuals at rest that were exclusively nasal breathing. These data are not indicative of how the device influences breathing during exercise at higher ventilations when a larger proportion of breathing is through the mouth. Accordingly, the purpose of this study was to empirically test the efficacy of the Turbine™ during exercise. We hypothesized that the Turbine™ would modestly reduce the WOB at rest and very low exercise intensities but would have no effect on the WOB at moderate to high exercise intensities.
Methods:
We conducted a randomized crossover study in young, healthy individuals (7M:1F; age = 27 ± 5 yr) with normal lung function. Each participant performed two incremental cycle exercise tests to exhaustion with the Turbine™ device or under a sham control condition. For the sham control condition, participants were told they were breathing a low-density gas to reduce the WOB, but they were actually breathing room air. The WOB was determined through the integration of ensemble averaged esophageal pressure-volume loops. Standard cardiorespiratory measures were recorded using a commercially available metabolic cart. Dyspnea was assessed throughout exercise using the 0-10 Borg scale.
Results:
Peak V˙O2 and work rate were not different between conditions (P = 0.70 and P = 0.35, respectively). In addition, there was no interaction or main effect of condition on dyspnea, ventilation, or WOB throughout the exercise (all P > 0.05).
Conclusion:
These findings suggest that the Turbine™ does not reduce the WOB and has no effect on dyspnea or exercise capacity.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:

