Three-Dimensional Assessments of Intraocular Lens Stability With High-Speed Swept-Source Optical Coherence Tomography
Purpose:
To evaluate the effect of intraocular lens (IOL) optic overlapping on IOL stability and to determine the relationship between the capsulorhexis and IOL movement with the three-dimensional method of swept-source optical coherence tomography (SS-OCT).
Methods:
This study identified patients with age-related cataracts and divided them into two groups according to their anterior capsule and IOL optic relationship: total anterior capsule overlap (360°) and partial anterior capsule overlap (< 360°). Standard SS-OCT radial scanning was performed in all eyes at 1 day, 1 week, 1 month, and 3 months after cataract surgery, respectively. The obtained photographs were used for the postoperative position measurements of capsulorhexis and IOL after three-dimensional reconstruction.
Results:
This study included 46 eyes of 34 patients: total overlap group (n = 29) and partial overlap group (n = 17). The postoperative aqueous depth significantly decreased in the first week after surgery (P < .001). The IOL tilt was greater in the partial overlap group than that in the total overlap group (P = .014). The IOL moved significantly in the first week postoperatively (both P < .001). IOL decentration in the x-axis was greater in the partial overlap group than that in the total overlap group (P = .024). The IOL and capsulorhexis both moved sharply in the first week (both P < .05). The IOL moved consistently with the capsulorhexis in the 3 months after surgery (all P > .05).
Conclusions:
The total overlap group showed better IOL centrality and stability. IOL movement may be driven by capsular bag contraction and fibrosis. Thus, it was demonstrated that postoperative IOL position and IOL performance were closely linked with proper size of central continuous curvilinear capsulorhexis. [J Refract Surg. 2020;36(6):388-394.].
More Related Videos
12:22Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT
Published on: August 4, 2018
08:50Longitudinal Morphological and Physiological Monitoring of Three-dimensional Tumor Spheroids Using Optical Coherence Tomography
Published on: February 9, 2019
Related Concept Videos
Imaging Studies III: Computed Tomography
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...