This study investigates the x-ray scattering characteristics of microsphere particles in x-ray-grating-based interferometric imaging at different concentrations, bubble sizes and tube voltages (kV). Attenuation (ATI), dark-field (DFI) and phase-contrast (PCI) images were acquired. Signal-to-noise (SNR) and contrast-to-noise ratios with water (CNRw) and air as reference (CNRa) were determined. In all modalities, a linear relationship between SNR and microbubbles concentration, respectively, microsphere size was found. A significant gain of SNR was found when varying kV. SNR was significantly higher in DFI and PCI than ATI. The highest gain of SNR was shown at 60 kV for all media in ATI and DFI, at 80 kV for PCI. SNR for all media was significantly higher compared to air and was slightly lower compared to water. A linear relationship was found between CNRa, CNRw, concentration and size. With increasing concentration and decreasing size, CNRa and CNRw increased in DFI, but decreased in PCI. Best CNRa and CNRw was found at specific combination of kV and concentration/size. Highest average CNRa and CNRw was found for microspheres in ATI and PCI, for microbubbles in DFI. Microspheres are a promising contrast-media for grating-based-interferometry, if kV, microsphere size and concentration are appropriately combined.
More Related Videos
07:48High Spatial Resolution Chemical Imaging of Implant-Associated Infections with X-ray Excited Luminescence Chemical Imaging Through Tissue
Published on: September 30, 2022
07:50Electron Channeling Contrast Imaging for Rapid III-V Heteroepitaxial Characterization
Published on: July 17, 2015
Related Concept Videos
X-ray Imaging
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...