Temperature measurement during superficial hyperthermia is limited by poor spatial resolution. We investigated two sheets to improve temperature monitoring of the skin surface. Two different sheets were studied with a grid of temperature sensors with one sensor per ∼5 cm2. The first was a matrix of multisensor thermocouple probes laced through a silicone sheet. The second sheet had rows of thermistors connected by meandering copper leads mounted on stretchable printed circuit board (SPCB). Accuracy, temperature resolution and two hour stability of both sheets were investigated. Furthermore, we determined the ability to follow body contours, thermal conduction errors and electromagnetic (EM) compatibility to clinically used 434 and 915 MHz hyperthermia applicators. For both sheets the accuracy (≤0.2 °C), temperature resolution (≤0.03 °C) and stability (≤0.01 °C hr-1) were adequate for clinical use. Thermal conduction errors ranged from 5.25-11.25 mm vs. 2.15 mm for the thermocouple probe and thermistor, respectively. Both sheets could follow body contours, where the ratio air/water bolus surface was <5%. When aligned perpendicularly to the EM field the meandering copper tracks used on the SPCB did induce self-heating, while the thermocouple probes did not. Self-heating had a linear relationship with the angle of the leads with respect to the EM field direction for both sensors at both frequencies. Self-heating of the thermistor was similar for both frequencies, while it was circa two-fold higher for 915 vs. 434 MHz for the thermocouple. The use of SPCB technology for skin surface monitoring was promising. However, suppressing self-heating induced by the horseshoe shaped copper tracks needed for stretchability of the SPCB requires more in-depth investigation. The thermocouple matrix was the most promising for clinical application, meeting 6/7 of the major requirements for skin surface temperature monitoring when positioned perpendicular to the EM field.
More Related Videos
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Decreased Body Temperature
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...