Related Experiment Video
Updated: Dec 18, 2025

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Retention Time and Ion Abundance Ratio of 8 Common Drugs (Poisons) by LC-MS/MS Qualitative Analysis
1School of Forensic Medicine, Shanxi Medical University, Taiyuan 030001, China.
Abstract:
Objective To investigate the maximum allowable deviations of retention time and ion abundance ratio of the 8 common drugs (poisons) from 3 categories, poisons (methamphetamine, morphine, ketamine), benzodiazepines (estazolam, midazolam, diazepam, clonazepam) and barbiturates (phenobarbital) in blood, by liquid chromatography-tandem mass spectrometry (LC-MS/MS) in forensic toxicology analysis. Methods The deviations of retention time and ion abundance ratio at 7 low mass concentrations, limit of detection (LOD), 2LOD, limit of quantitation (LOQ), 1.5LOQ, 2LOQ, 4LOQ and 6LOQ, were tested by LC-MS/MS after liquid-liquid extraction under the conditions of two chromatographic columns and three chromatographs. Results The deviation of absolute retention time of 98.11% of 8 drugs (poisons) in the blood samples was within the range of ±0.05 min, and that of the relative retention time of 96.21% was within the range of ±0.4%. The maximum deviation of the ion abundance ratio was highly correlated with the mass concentration. When the mass concentration of drugs (poisons) was LOQ or above, more than 95% of the absolute deviation and relative deviation of the ion abundance ratio were in the range of ±25% and ±40%, respectively; when the mass concentration was below LOQ, the range could be expanded to ±35% and ±50%, respectively. Conclusion It is recommended for the determination range of the absolute retention time deviation of 8 common drugs (poisons) to be ±0.1 min and that of the relative retention time deviation to be ±1.0%. The determination range of absolute deviation of the ion abundance ratio should be ±25% when the mass concentration is LOQ or above, and the relative deviation should be ±40%. When the mass concentration is below LOQ, the deviation determination range can be expanded to ±35% and ±50%, respectively.
Related Concept Videos
Enhanced Elimination of Poison
Antidotes serve a crucial role in counteracting the effects of poison by inhibiting enzymes responsible for producing harmful drug metabolites. In some cases, these toxic metabolites can be neutralized by endogenous cosubstrates, which are maintained at specific concentrations to prevent interaction with cellular macromolecules and subsequent cell death.
Renal excretion is the...
Drug Concentrations: Measurements
Plasma...
Ion-Exchange Chromatography
Drug Dissolution: Requirements and Profile Comparison