1Department of Maxillofacial Surgery, Medical University of Lodz, 1st Gen. J. Haller Pl., 90-647 Lodz, Poland.
Magnesium screws show promise for craniofacial bone repair, exhibiting superior pull-out strength compared to titanium and polymer screws. However, magnesium screws demonstrated lower torsional strength than titanium screws.
Area of Science:
- Biomaterials Science
- Orthopedic Surgery
- Materials Engineering
Background:
- Magnesium alloys are increasingly recognized for their potential as degradable biomaterials.
- Applications include biodegradable implants for craniofacial bone repair, such as screws.
Purpose of the Study:
- To compare the mechanical properties of different screws used for mandibular head osteosynthesis.
- Evaluate pull-out strength and torsional properties of magnesium, titanium, and polymer screws.
Main Methods:
- Selected 14 mm screws for mandibular head osteosynthesis made of magnesium (MgYREZr), titanium (Ti6Al7Nb), and polymer (PLGA).
- Investigated axial pull-out strength and torsional properties of each screw type.
Main Results:
- Magnesium screws exhibited the highest pull-out force (399 N), followed by titanium (340 N) and PLGA (138 N).
- Titanium screws had higher maximal torque (19 N·cm) compared to magnesium screws (16 N·cm).
- Magnesium screws were significantly weaker in torsion than titanium screws (p < 0.05).
Conclusions:
- Biodegradable magnesium screws appear most suitable for multiscrew mandibular head osteosynthesis due to their high pull-out strength.
- Consideration of the fragile screwdriver socket favors magnesium screws in this application.