Related Experiment Video
Updated: Dec 18, 2025

Implantation and Monitoring by PET/CT of an Orthotopic Model of Human Pleural Mesothelioma in Athymic Mice
Published on: December 21, 2019
Are volume-dependent parameters in positron emission tomography predictive of postoperative recurrence after
Masatsugu Hamaji1, Sho Koyasu2, Mitsugu Omasa3
1Department of Thoracic Surgery, Kyoto University Hospital, 54 Kawahara-cho, Sakyo-ku, Kyoto, 604-0984, Japan. mhamaji@kuhp.kyoto-u.ac.jp.
Abstract:
This study aimed to investigate the association between the volume-dependent parameters in 18F-fluorodeoxyglucose-positron emission tomography (18F-FDG PET/CT) and a recurrence of thymic carcinoma. A retrospective chart review was performed based on our multi-institutional database to identify patients undergoing PET prior to resection of thymic carcinoma or neuroendocrine carcinoma between 1991 and 2018. The PET parameters (metabolic tumor volume and total lesion glycolysis) were evaluated retrospectively. The relevant factors were extracted and a survival analysis was performed using the Kaplan-Meier method. Sixteen patients were thus deemed to be eligible for analysis. The median follow-up period following resection was 2.65 years (range: 0.96-0.68 years). The recurrence-free survival was significantly longer in patients with a metabolic tumor volume < = 22.755 cm3 and with total lesion glycolysis < = 105.4006 g/mL (p = 0.001 and 0.001, respectively, by a log-rank test). The metabolic tumor volume and total lesion glycolysis may, therefore, be predictive of the postoperative recurrence of thymic carcinoma.
More Related Videos
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
10:48PET and MRI Guided Irradiation of a Glioblastoma Rat Model Using a Micro-irradiator
Published on: December 28, 2017
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...