Related Experiment Video
Updated: Dec 18, 2025

Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
Testing experimental designs in liquid chromatography (I): Development and validation of a method for the
J A Navarro-Huerta1, A Gisbert-Alonso1, J R Torres-Lapasió2
1Department of Analytical Chemistry, Faculty of Chemistry, Universitat de València, C/ Dr. Moliner 50, 46100, Burjassot, (Spain).
Abstract:
The basis of interpretive optimisation in liquid chromatography is the prediction of resolution, from appropriate solute retention models. The reliability of the process depends critically on the quality of the experimental design. This work develops, validates and applies a general methodology aimed to evaluate the quality of any training experimental design, which will be applied in Part II to design optimisation. The methodology is based on the systematic evaluation of the uncertainties associated to the prediction of retention times in comprehensive scans of both isocratic and gradient experimental conditions. It is able to evaluate comprehensively experimental designs of arbitrary complexity. Five common training experimental designs were used to model the retention, according to the Linear Solvent Strength (LSS) and the Neue-Kuss (NK) equations, using a set of 14 sulphonamides of different polarity. The results are presented in terms of relative uncertainties in predictions, which provide significant and interpretable results. The magnitude of such uncertainties, together with the systematic, coherent and logical changes observed at increasing solute hydrophobicity, give support to the results. The NK model gave smaller errors and unbiased predictions, whereas the LSS model gave rise to lack of fit. Isocratic training designs, which are widely accepted as the most informative, are confirmed as the best. As a general conclusion, gradients are predicted with intrinsically smaller uncertainties, independently of the training experimental design. In addition, gradients are more insensitive than isocratic predictions with regard to the type of training design used. Isocratic predictions deteriorate quickly with mobile phase composition. This explains the better performance of gradient predictions, even with biased models.
Related Concept Videos
High-Performance Liquid Chromatography: Instrumentation
Data Validation
Key parameters for method validation include:
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Types of Detectors
Principles Of Column Chromatography