Rendering A Chiral Screening Step In Supercritical Fluid Chromatography Mass-Spectrometry Compatible
Sven Declerck1, Yvan Vander Heyden1, Debby Mangelings1
1Department of Analytical Chemistry, Applied Chemometrics and Molecular Modelling, Vrije Universiteit Brussel (VUB), Laarbeeklaan 103, 1090 Brussels, Belgium.
Abstract:
Nowadays, sensitive chiral methods are required for the determination of chiral impurities and for assays in biological samples. Supercritical fluid chromatography (SFC), one of the main techniques to separate chiral molecules, can be coupled to MS to provide such sensitive methods. Moreover, chiral separation strategies are very useful to reduce the development time and cost of such methods. This study investigates the transfer of an existing non-MS compatible screening step (as part of a separation strategy) into an MS-compatible one. The initial step had a cumulative success rate of 100 % for 57 tested compounds using methanol or 2-propanol as mobile phase modifier on one of four chiral stationary phases. The additives applied in the original mobile phases, i.e. isopropylamine and trifluoroacetic acid, negatively affect the ionization in SFC-MS and thus need to be replaced. Formic acid, acetic acid, water, ammonia, ammonium acetate and ammonium formate were investigated as MS-compatible additives in different combinations and concentrations. Only methanol-based mobile phases were considered in this study because high system pressures were obtained with isopropanol. The other experimental parameters remained the same as in the initial screening step. The effects of the alternative additives on the obtained resolutions as well as on the global success rate were investigated. The best alternative MS-compatible mobile phase contained 0.5 % CH3COOH and 40 mM NH3 as additives. This mobile phase provided the highest number of separations and rather high resolutions. An MS-compatible screening step was defined with this alternative mobile phase. Compared to the original additives, a similar success rate was obtained.
Related Concept Videos
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...