The effect of contrast material on radiation dose during computed tomography pulmonary angiography
Haleh Karami1, Hashem Miri-Hakimabad1, Elie Hoseinian-Azghadi1
1Physics Department, Faculty of Science, Ferdowsi University of Mashhad, Mashhad, Iran.
Abstract:
This study evaluated the impact of contrast material (CM) on radiation dose for adults undergoing computed tomography pulmonary angiography (CTPA). A previously developed physiologically based pharmacokinetic (PBPK) model and phantoms representing the average (reference) adult male and female individual were used to evaluate the iodine concentration in tissues as a function of time elapsed since the initiation of iodinated contrast medium administration. In order to estimate the radiation dose more accurately, a detailed model of pulmonary vessels was added to the phantoms. Then, the material composition of phantoms was modified to include the iodine concentration in different organs and tissues at different acquisition times after CM injection. The calculations were performed using Monte Carlo N-Particle extended code (MCNPX) version 2.6.0. The radiation dose estimates during CTPA were provided as a function of scan acquisition time after injection considering the distribution of iodinated CM within ICRP reference phantoms. It was shown that the estimated radiation dose to the lungs could be 31-40% (27-34%) larger when considering the effect of iodinated contrast administration with injection rate of 5 (3)mL/s. Moreover, the effective dose for contrast-enhanced CT (CECT) would be utmost 10-13% larger than that for non-enhanced CT (NECT). The radiation doses to the other organs in-/outside the scanned region would be decreased if the scan performed on time. In case of late scanning, absorbed dose decreases slightly for lungs (∼15-20%) whereas becomes (∼10% or more) higher than its NECT value for some organs such as heart muscle, kidneys, and spleen. To sum up, the late scanning (Δt>5s after the end of injection) is not recommended because of higher dose delivered to other organs than the lungs (particularly heart muscle).
More Related Videos
12:15Tissue Preparation Techniques for Contrast-Enhanced Micro Computed Tomography Imaging of Large Mammalian Cardiac Models with Chronic Disease
Published on: February 8, 2022
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...