Excellent Hemodynamic Performance After Aortic Valve Neocuspidization Using Autologous Pericardium
Markus Krane1, Johannes Boehm2, Anatol Prinzing2
1Department of Cardiovascular Surgery, German Heart Center Munich, Technical University Munich, Munich, Germany; Insure (Institute for Translational Cardiac Surgery), Department of Cardiovascular Surgery, German Heart Center, Technical University Munich, Munich, Germany; DZHK (German Center for Cardiovascular Research), Partner Site Munich Heart Alliance, Munich, Germany.
Background:
Aortic valve neocuspidization (AVNeo) for trileaflet aortic valve reconstruction using autologous pericardium (Ozaki procedure) offers an alternative treatment modality to overcome drawbacks of conventional prosthetic aortic valve replacement.
Methods:
Between October 2016 and April 2019, 103 patients underwent surgery. Mean follow-up was 426 ± 270 days. Aortic stenosis was the leading diagnosis in 80 patients (77.7%) and aortic regurgitation in 23 (22.3%), respectively. Mean age was 54.0 ± 16.4 years (range, 13.8-78.5). A bicuspid valve was found in 81 patients (78.6%). Transthoracic echocardiography was performed at discharge and at 6 to 12 months after surgery. During AVNeo surgery valve sizing for an Abbott/St Jude Trifecta bioprosthesis (virtually implanted Trifecta bioprosthesis; St Jude Medical, St Paul, MN) was performed to compare pressure gradients and effective orifice area with published data.
Results:
Trileaflet aortic valve reconstruction was achieved in all patients. In 38 patients neocommissures were created (36.9%). Mean cross-clamp time was 135 ± 20 minutes. Four patients underwent reoperation; the overall freedom from reoperation was 96.1%. Echocardiographic 6- to 12-months follow-up after surgery was available in 93.8% of patients and did not show any change in hemodynamic parameters compared with discharge. Comparison between AVNeo and virtually implanted Trifecta Bioprosthesis revealed a significantly lower mean pressure gradient (8.5 ± 3.7 mm Hg vs 10.2 ± 2.0 mm Hg, P < .001) and higher mean effective orifice area (2.2 ± 0.7 cm2 vs 2.1 ± 0.4 cm2, P = .037) for AVNeo.
Conclusions:
AVNeo shows low reoperation rates after surgery within the first 2 years. The hemodynamic performance is excellent, and the effective orifice area and mean pressure gradient remain stable within the first year.
More Related Videos
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
12:17Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
Related Concept Videos
Aortic Regurgitation I: Introduction
Aortic Regurgitation III: Medical Management